Riello Sentinel RT systems range from 1-10kva and are rack/tower mountable with online double conversion protection and extended runtime capable with external battery pack options.

Features & Benefits
- Digital LCD touchscreen display
- Hot swappable batteries
- Internal isolation transformer
- Wide input voltage & frequency windows
- Input power factor > 95 percent
- Power factor correction
- Output power factor 85 percent
- Optional network interface card for remote monitoring/control
- Optional external battery cabinets
- Optional environmental monitoring device
Technical Specs
1600XP/XPi Specifications Spreadsheet
|
|||||||
Capacity |
3.6 KVA
(3.1 KW) |
6 KVA
(5.1 KW) |
8 KVA
(6.8 KW) |
10 KVA
(8.5 KW) |
14 KVA
(11.9 KW) |
18 KVA
(15.3 KW) |
22 KVA
(18.7 KW) |
Topology |
True On-Line, Double Conversion; IGBT Power Factor Corrected Input; Internal Isolation Transformer
|
||||||
Certifications |
UL 1778, CUL, CE, FCC Class A, IEEE 587, ANSI/C62.41, ISO 9001, ISO 14001, NEMA/PE1-1993, RoHs
|
||||||
Input Characteristics | |||||||
Input Voltage (Based on Typical 70% Load) |
Single-Phase 208/240 VAC (Three-Wire Input/L-L, G); 230 VAC (Three-Wire Input/L, N, G), +10% -30%
|
||||||
Input Frequency |
45 to 65 Hz (Auto-Sensing)
|
||||||
Input Power Factor |
> 0.95 For All Loads
|
||||||
Input Current THD |
< 5% (Even for 100% Non-Linear Loads)
|
||||||
AC Input Breaker Rating |
30 A
|
50 A
|
60 A
|
63 A
|
100 A
|
100 A
|
125 A
|
Battery Characteristics | |||||||
Battery Type |
Valve-Regulated Lead Acid; Flame Retardant (9.0 Amp Hr)
|
||||||
Backup Time (Fully Charged) |
7 Minutes
|
7 Minutes
|
7 Minutes
|
5 Minutes
|
7 Minutes
|
5 Minutes
|
3 Minutes
|
0.85 Power Factor; 77° F; Approximately 30% More Runtime for Output Power Factor of 0.7 (Triple Backup Time at ½ Load)
|
|||||||
Recharge Time |
24 Hours (Full), 12 Hours (90%)
|
||||||
DC Link |
144 VDC
|
216 VDC
|
288 VDC
|
||||
Output Characteristics | |||||||
Output Voltage |
Single-Phase 240/208/120 VAC (Four-Wire Output/L-L, N, G) 230 VAC (Three-Wire Output L, N, G)
|
||||||
Output Voltage Regulation |
3%; ±1% Typical
|
||||||
Output Frequency |
50/60 Hz; ±0.5 Hz/1.0 Hz/1.5 Hz (Factory or Authorized Service Center Selectable)
|
||||||
Output Voltage THD |
< 3% for Linear Load; 1% Typical
|
||||||
Common Mode Noise |
< 0.5 V RMS
|
||||||
Rated-Load Power Factor |
0.85 (0.6 to 1.0) Lag
|
||||||
Rated Output Current @ 240 V |
15 A
|
25 A
|
33.3 A
|
41.6 A
|
58 A
|
75A
|
91.6 A
|
Maximum Peak Output Current |
45 A
|
75 A
|
100 A
|
125 A
|
174 A
|
225 A
|
275 A
|
Overload Capacity |
Inverter Mode: 150% for 10 Seconds, 125% for 30 seconds; Bypass Mode: 125% for 10 Minutes, 1000% for One Cycle
|
||||||
Environmental Characteristics | |||||||
Efficiency (AC-DC-AC) |
> 85%
|
||||||
Temperature Range |
0 to 40°C (Operating); -20° to +40°C (Storage)
|
||||||
Heat Generation (BTU/Hr) |
1843
|
3071
|
4095
|
5118
|
7168
|
9213
|
11,260
|
Altitude |
6600 Feet (2000 Meters) Maximum Without Derating
|
||||||
Audible Noise |
< 60 DBA @ 1 Meter
|
||||||
Mechanical Design | |||||||
Enclosure |
Steel Enclosure; Complies with NEMA 1 and UL Type-1 Standard
|
||||||
Enclosure Dimensions (HxWxD) |
22.1″ x 10″ x 33″
|
27.5″ x 10″ x 33″
|
28.4″ x 13″ x 34.9″
|
39.1″ x 17.5″ x 36.1″
|
|||
Shipping Weight |
280 lb/127 kg
|
346 lb/157 kg
|
476 lb/214 kg
|
784 lb/355 kg
|
784 lb/355 kg
|
835 lbs/379 kg
|
|
Battery Pack Size (HxWxD) |
5″ x 7.3″ x 19″ (Battery Pack Part # 51896-FS)
|
||||||
Battery Pack Quantity |
Two
|
Three
|
Four
|
Eight
|
|||
Additional Key Features |
Output Isolation Transformer, RS232 & Dry Contact Interface, Crest Factor of 3, Angled Terminal Blocks for Easy Installation, Casters for Mobility
|
||||||
Options | |||||||
SNMP & WEB-Based Monitoring |
RemotEye® III, RemotEye® 4, RemotRadar™, & Environmental Monitoring Device
|
||||||
Matching Battery Cabinet |
Consult Factory
|
||||||
Internal/External Maintenance Bypass |
Consult Factory
|
||||||
Receptacle Panel & Line Cord |
Consult Factory
|
||||||
Warranty |
Three Years on Electronics (UPS); Two Years on Battery (See Toshiba Warranty Policy for Full Details)
|
Industries & Applications
- Industrial Systems
- Health Care
- Laboratories
- Small Business Offices
- Point-of Sale Equipment
- Internet Service Provider
- Server Consolidation
- Datacenters
- Storage
- Wiring Closets
We respect your privacy and will never share your email address with anyone without your explicit permission.

intelligent charger with rapid charge in only 4.0 hours to 90 percent. Wide input voltage and frequency windows maximize generator compatibility. Input power factor is greater than 97 percent with an output power factor of 70 percent (0.8 PF for 2.4 KVA). LCD displays in multiple languages. Options include network interface card (RemotEye® II) environmental monitoring device. Available in 1.0, 1.5, 2.0, 2.4, 3.0, and 6.0 KVA.
Features & Benefits
- Auto-restart and cold start
- Programmable load-shed receptacle
- Intelligent charger with rapid charge in only 4.0 hours to 90 percent
- Wide input voltage window
- Wide input frequency window for comp generator compatibility
- Input power factor > 97 percent
- Output power factor 0.70 (0.8 PF for 2.4KVA)
- LCD display in multiple languages
- Optional network interface card – RemotEye® II
- Optional environmental monitoring device
Technical Specs
1000 Series Specifications
|
||||||||
Category |
1000 Series
|
1000+ Series
|
||||||
Size |
1000 VA
|
1500 VA
|
2000 VA
|
3000 VA
|
6000 VA
|
1000 VA
|
2400 VA
|
|
Tower | US 120V Model |
UT1A1A010C6
|
UT1A1A015C6
|
UT1A1A020C6
|
UT1A1A030C6
|
–
|
UT1A1A010C6T
|
UT1G2L024C6T
|
International 230V Model |
UT1E1E010C6
|
UT1E1E015C6
|
UT1E1E020C6
|
UT1E1E030C6
|
–
|
–
|
–
|
|
Rackmount (2U) | US 120V Model |
UT1A1A010C6RKB2
|
UT1A1A015C6RKB2
|
UT1A1A020C6RKB2
|
UT1A1A030C6RKB2
|
–
|
–
|
|
International 230V Model |
UT1E1E010C6RKB2
|
UT1E1E015C6RKB2
|
UT1E1E020C6RKB2
|
UT1E1E030C6RKB2
|
UT1G1G060C6RKB3 + UT1-BR-0607
|
–
|
–
|
|
Input | Voltage |
120 VAC (80 – 144 V, +20% to -33%)
|
–
|
120 VAC
|
Single-Phase 208/240 VAC (Three-Wire Input/L-L, G) (160 – 276 V, +15% to -34%)
|
|||
Voltage (International) |
230 VAC (161 – 276 V, +20% to -30%)
|
–
|
||||||
Capacity (VA) |
1000 VA
|
1500 VA
|
2000 VA
|
3000 VA
|
6000 VA
|
1000 VA
|
2400 VA
|
|
Capacity (W) |
700 W
|
1050 W
|
1400 W
|
2100 W
|
4200 W
|
700 W
|
1920 W
|
|
Frequency |
50 / 60 Hz auto sensing
|
|||||||
Power Factor |
Greater than 0.97
|
|||||||
Topology |
True on-line, Double conversion, Input PF correction
|
True on-line, Double conversion, Input PF correction Isolation Transformer
|
||||||
Output | Voltage |
100/110/115/120/127 VAC
|
–
|
100/110/115/120/127 VAC
|
120/200/208/220/230/240 VAC
|
|||
Voltage (International) |
208/220/230/240 VAC
|
|||||||
Frequency |
50 / 60 Hz auto sensing
|
|||||||
Wave Form |
Sine wave, zero transfer time
|
|||||||
Load Power Factor |
0.7
|
0.8
|
||||||
Efficiency AC/DC/AC |
Greater than 86%
|
> 89 %
|
> 86%
|
> 87%
|
||||
Rated Current |
8.3 A
|
12.5 A
|
16.6 A
|
25 A
|
–
|
8.3 A
|
10A (240V)
|
|
Rated Current (International) |
4.3 A
|
6.5 A
|
8.7 A
|
13 A
|
25 A (240V)
|
–
|
||
Overload Capacity |
125% for 1 min, 130% for 10 sec
|
|||||||
Crest Factor |
3.0 at full load
|
|||||||
Battery | DC Voltage (Tower & 2U) |
36 V / 12 V 9 AH x 3
|
72V / 12 V 9AH x 6
|
240V 12V x 20
|
36 V / 12 V 9 AH x 3
|
72V / 12 V 9AH x 12 (2 strings)
|
||
Backup Time (Tower & 2U) |
7 min (full load)
|
6 min (full load)
|
6 min (full load)
|
5 min (full load)
|
7 min (full load)
|
11 minutes
|
||
Type |
Valve-Regulated Lead Acid; Flame Retardant (9.0 Amp Hr)
|
|||||||
Physical | Interface |
RS-232 and USB standard, Remote Contact, RemotEye II© and EMD option
|
||||||
Dimensions Tower (L X W X H) |
16.5″ x 6.0″ x 9.4″
|
16.7″ x 8.9″ x 14.2″
|
–
|
23.3″ x 6.0″ x 9.4″
|
23.2″ x 10.1″ x 27.6″
|
|||
Dimensions 2U (L X W X H) |
16.7″ x 16.9″ x 3.5″
|
25.0″ x 16.9″ x 3.5″
|
16.8Lx23.5Wx10.5H (6U)
|
–
|
||||
Weight (Tower/2U) |
35.6 lbs / 37.6 lbs
|
37.4 lbs / 37.6 lbs
|
68.4 lbs /69.5 lbs
|
72.6 lbs / 71.5 lbs
|
148 lbs
|
51 lbs
|
154.3 lbs
|
|
Line Cord |
5-15P
|
5-20P
|
L5-30P
|
–
|
5-15P
|
Hardwire or Optional L6-20P
|
||
Line Cord (International) |
IEC 320
|
Hardwire & L6-30P
|
–
|
|||||
Receptacles (Tower/2U) |
NEMA 5-15R (6/6)
|
NEMA 5-20R (12/4)
|
L6-30R (2)
|
NEMA 5-15 (6)
|
Hardwire/Optional (3) 5-20R or (2) L6-20R & (1) 5-20R Duplex
|
|||
Receptacles (Tower/2U) International |
IEC 320 C13 (4/4)
|
IEC 320 C13 (4/4)
|
IEC 320 C13 (8/4)
|
IEC 320 C13 (8/4)
|
–
|
|||
Environment | Operating Temperature |
0 – 40oC (32 – 104oF)
|
||||||
Altitude |
11500 ft (3500 m) above sea level
|
|||||||
Warranty |
Three years on electronics
|
|||||||
Two years full replacement on battery (See Toshiba warranty policy for full details.)
|
Industries & Applications
- Industrial Systems
- Health Care
- Laboratories
- Small Business Offices
- Point-of Sale Equipment
- Internet Service Provider
- Server Consolidation
- Datacenters
- Storage
- Wiring Closets
We respect your privacy and will never share your email address with anyone without your explicit permission.
Easy to install and maintain, and versatile enough to accommodate office environments as well as more-demanding commercial and industrial ones, the LP 11 Series by GE is a true-voltage, frequency-independent, double conversion, online UPS system designed to provide the highest level of protection for all critical loads against all utility variances and failure.
Highly scalable, the GE proprietary redundant parallel architecture allows you to parallel up to four units as increasing business growth might require, as well as simultaneously enhancing total system reliability, and eliminating the possibility of single points of failure.
Ergonomically designed LCD interface provides clear status data, functions as a service screen to adjust UPS parameters, and includes a comprehensive event log. Integrated transformer ensures galvanic isolation on the output for ultimate safe installation. Available with optional matching battery cabinets to extend runtime, the LP 11 Series comes with a comprehensive warranty.
Features & Benefits
- High efficiency at all loads
- Can operate between 0°C to 40°C
- Advanced battery protection
- Hot-swappable batteries
- Regular automatic battery test
- Short circuit and overload protection
- Cold start
- 50/60 auto-sensing—can be used as a frequency converter
- Energy-saving eco-friendly 95 percent efficiency
- At-a-glance LED display of system status
Product Scope
Single Phase Output Voltages | 120/208/230/240V |
Wide input voltage window | Minimizes battery use, prolongs battery life |
RPA functionality for paralleling and redundancy | UPS capacity can be increased as site requirements require at no extra cost |
Internal automatic bypass switch | Continuous power supply to the load even if the UPS is overloaded |
0.8 output power factor | Prevents the need to oversize the UPS |
0.99 input power factor | |
Manual automatic bypass switch | Integrated as standard to the rear of the UPS |
GE’s unique Superior Battery Management | Ultimate protection for the UPS core component |
High efficiency 91% – 94% (model dependent) | Using ECO mode, high efficiency and low losses |
No load shutdown | Prevents deep battery discharge al low loads |
Frequency conversion 50/60Hz | Operates as a frequency converter also operating in a parallel system |
Technical Specs
GE LP-11U Series UPS (5kVA-10kVA) Technical Specifications | ||||||
---|---|---|---|---|---|---|
MODEL NUMBER | LP11U-5 | LP11U-5 (120) | LP11U-6 | LP11U-6 (120V) | LP11U-8 | LP11U-10 |
Rating (VA/W) | 5000 / 4000 | 5000 / 4000 | 6000 / 4800 | 6000 / 4800 | 8000 / 6400 | 10,000 / 8000 |
Backup Time @ 50% / 100% loads | 25 / 10 min. | 25 / 10 min. | 20 / 8 min. | 20 / 8 min. | 29 / 11 min. | 22 / 8 min. |
Enclosure (Table 1) | A | B | A | B | A | A |
Net Wgt Incl. Batteries (kg/lbs) | 134/295 | 175/386 | 134/295 | 175/386 | 175/386 | 186/410 |
Input Voltage (VAC) | ||||||
Nominal | 208 | 120 | 208 | 120 | 208 | 208 |
Range @ 100% Load (V) | 162-285 | 81-141 | 162-285 | 81-141 | 162-285 | 162-285 |
Range @ 50% Load (V) | 146-285 | 72-141 | 146-285 | 72-141 | 146-285 | 146-285 |
Input Power Factor | .99 | |||||
Input Frequency (Hz) | 40-70 | |||||
Output Power Factor | .8 | |||||
Output Voltage (VAC) (sinusoidal) | 120+208+220/230/240 User Selectable | |||||
Output Frequency (Hz) | 50/60 | |||||
Output Voltage Regulation | +/- 1% | |||||
Output THD at Linear Load | <1% | |||||
Output THD at Non-linear Load | <2% | |||||
Crest Factor Handling Capacity of a Non-linear Load | 5:1 | |||||
Overload Capability on Inverter | 110% 20 min., 130% 3.5 min., 150% 2 min. | |||||
Color | Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010) | |||||
Environment | IP20 (IEC 60529) | |||||
Operating Temperature / Humidity | 32° F – 104° F (0° C – 40° C) / 95% Non-condensing | |||||
Audible Noise | 40-50 dBA – 3.3 feet (1 meter) | |||||
Safety Classifications & Listings | UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950 | |||||
EMI | FCC Part 15 Class A / EN50091-2 | |||||
Surge Protection | IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2 | |||||
Connectivity | RS-232; programmable alarm contacts (optional); SNMP (optional) | |||||
Warranty | 24 Months |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
- Hospitals, clinics, medical centers
- Government & business offices
- Police & fire emergency call centers
- Military applications
- “Lights-out” or “dark factory” manufacturing
- Large data centers or IT systems
- Critical network switching & processing equipment
- Large-scale PLC controls
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Fully-digitized microprocessor control for reliable performance
- At-a-glance LED display of system status
- Programmable outlet allows selective shutdown for lower priority loads
- Quiet operation is ideal for office and medical environments
- Advanced battery protection
- Cold start capability
- Hot swappable batteries
- Multiple PDU options
Product Specifications
GT Series UPS – UL Listed (3kVA) | |
---|---|
Single Phase Output Voltage | 110V with 208V optional on 3kVA units |
Wide input voltage window 80-138V | Minimizes battery use, prolongs battery life |
Pulse Width Modulation technology | Eliminates the need to oversize the UPS |
Internal automatic bypass switch | Continuous power supply to the load even if the UPS is overloaded |
Low input distortion | Prevents disturbance to nearby electrical equipment |
GT Series UPS – UL Listed (5-10kVA) | |
---|---|
Single Phase Output Voltages | 120/208V |
Wide input voltage window 80-138V | Minimizes battery use, prolongs battery life |
Redundant and paralleling capability | UPS capacity can be increased as site requirements require at no extra cost |
Internal automatic bypass switch | Continuous power supply to the load even if the UPS is overloaded |
No load shutdown | Prevents deep battery discharge al low loads |
Frequency conversion 60/50Hz | Automatic frequency detection |
Technical Specs (3kVA)
GT Series UPS Technical Specification (3kVA) | |
---|---|
MODEL NUMBER | GT3000R , GT3000T208 |
RATING (VA/W) | 3000 / 2400 , 3000 / 2400 |
BATTERY (V/Ah) | 2000VA/1200W , 3000VA/1800W |
BACKUP TIME @50% LOAD (25°C) | 14 min. |
OPTION FOR ADDITIONAL BATTERIES | Yes |
DIMENSIONS (HxWxD) | 13.2×43.9×50.3cm (5.2×17.3×19.8in) , 37.3x14x42.4cm (14.7×5.5×16.7in) |
NET WGT INCL. BATTERIES (kg / lbs) | 34 / 74.9 , 30 / 66 |
INPUT VOLTAGE @ 100% LOAD (VAC) | 80-138 , 160-275 |
INPUT FREQUENCY (Hz)* | 50/60 |
OUTPUT VOLTAGE | 100/110 , 160/208 |
NUMBER OF OUTLETS | (4)NEMA 5-15R , (4)NEMA 6-20R (1)NEMA L5-20R , (1)NEMA L6-20R (1)NEMA L5-30R |
SNMP COMPATIBILITY | Yes |
CORE VOLTAGE | 120 |
PWM (PULSE WIDTH MODULATION) | Yes |
MAINTENANCE BYPASS | Yes |
INTERNAL BATTERIES | Yes |
INPUT PERFORMANCE RANGE | Voltage (-33 to +17%); Frequency (55 to 65 Hz) |
OUTPUT PERFORMANCE | |
OUTPUT THD LOAD | Non-Linear (<6%); Linear (<3%) |
VOLTAGE REGULATION LOAD | Static (2%); 0-100% Step (8%) |
OVERLOAD CAPABILITY | 150% for 30 seconds |
EFFICIENCY | >87% |
COMMUNICATIONS INTERFACE | RS-232, Plug and Play, open collector alarm contacts |
COLOR | Front bezel: Aluminum Grey (RAL9006); Cabinet: White (RAL9010) |
OPERATING TEMPERATURE | 32° F – 104° F (0° C – 40° C) |
RELATIVE HUMIDITY | 95% non-condensing |
AUDIBLE NOISE AT 3.3FT (1 METER) | 47 dBA , 42 dBA |
SAFETY | UL 1778, CSA22.2-107, IEEE 62.41 CAT. A Lightning Safety |
EMC | FCC Class B (1kVA), FCC Class A (remaining), CISPR PUB. 22 Class A |
ENCLOSURE | NEMA1 |
GT Series UPS Technical Specification (5-10kVA) | ||||
---|---|---|---|---|
MODEL NUMBER | GT5000 RT | GT6000 RT | GT8000 RT | GT10000 RT |
RATINGS : | ||||
Power Rating Depending on Input Voltage | VA/W | VA/W | VA/W | VA/W |
100V / 200V | 4000 / 3400 | 4800 / 3400 | 6400 / 6400 | 8000 / 6400 |
110V / 220V | 4500 / 3800 | 5400 / 3800 | 7200 / 7200 | 9000 / 7200 |
115V / 230V | 5000 / 4000 | 60000 / 4200 | 8000 / 6900 | 8700 / 8000 |
120V / 208V | 4800 / 4200 | 5200 / 4200 | 8000 / 6900 | 8700 / 8000 |
120V / 240V | 5000 / 4200 | 6000 / 4200 | 8000 / 8000 | 10000 / 8000 |
127V / 220V | 4800 / 4200 | 5200 / 4200 | 8000 / 6900 | 8700 / 8000 |
Input Thermal Circuit Breaker (A) | 30 | 60 | ||
Internal Input Fuse 250V, Slow (A) Qty | 30 | 30/2 | ||
INPUT CONVERTER : | ||||
AC Input Voltage | Nominal:120/208V | |||
AC Input Voltage Range | 100/(173-200), 110/(190-220), 115/(198-230), 120/(208-240), 127/(220) V | |||
Input Current Waveform | Sine Wave | |||
Input Current (A) at Nominal Input Voltage | 20 | 40 | ||
Input Power Factor | >0.97 | |||
Input Frequency Range | 40 – 70 Hz | |||
Input phase (L1 to L2) | 120° / 180° / 240° ±10° | |||
Inrush Current | 40 | |||
OUTPUT CONVERTER : | ||||
AC Output Voltage | 100 / 110 / 115 / 120 / 127 V (selectable) | |||
AC Output Voltage Tolerance | L-N ± 3%; L1-L2 ± 5% | L-N ± 2%; L1-L2 ± 5% | ||
Output Frequency | 50 / 60 Hz, auto selection | |||
Output Frequency Range | nominal ± 5% with mains synchronizing | |||
Output Waveform | Sine wave | |||
Harmonic Distortion | < 3% with linear load, < 5% with non-linear full load | |||
Power Factor at Nominal Input Voltage | 0.87 | 0.8 | 0.86 | 0.92 |
Crest Factor (Peak to RMS Current) | ≤ 3 : 1 | |||
Capacity Appliance Outlets | with 55A Terminal Block | |||
BYPASS : | ||||
AC Input Voltage Range | ± 15% of selected output voltage | |||
Frequency Tracking Rate | 1Hz/s | |||
Frequency Tracking Range | ± 5% of selected frequency | |||
Typical Transfer Time, msec | 0 | |||
OVERLOAD CAPABILITY : | ||||
Overload Behavior During Battery Operation | 130% for 10 seconds 200% for 2 seconds |
130% for 1 minute 200% for 5 seconds |
||
Overload Behavior During Bypass Operation | Depends on rating of thermal circuit breaker (TCB) 125% of TCB value for 200 seconds 200% of TCB value for 10 seconds 300% of TCB value for 4 seconds |
Overload protection 110% of TCB value for 300 seconds 130% of TCB value for 30 seconds 200% of TCB value for 5 seconds |
||
BATTERIES (RATINGS GIVEN FOR 25º C) : | ||||
Nominal Voltage(Vdc) | 144 | 288 | ||
Qty / Ah (In Battery Kit & Battery Ext. Pack) | 12 pcs / 8Ah | 24 / 8Ah | ||
Type | REW45-12 FR | |||
Recharge Current | 1A | |||
Battery Recharge Time (Batt. Discharged at 100% Load) | 6 hours for 90% capacity | 3 hours for 90% capacity | ||
GENERAL : | ||||
Weight UPS | 30.3 Kg (67 lbs) | 49.3 Kg (109 lbs) | ||
Dimensions UPS (HxWxD) | 176x430x592 mm (6.9×16.9×22.55 in) | 267x430x660 mm (10.5×16.9×26 in) | ||
Weight Battery Pack | 43 Kg (94.7 lbs) | 91 Kg (200.4 lbs) | ||
Dimensions Battery Pack | 87x430x592 mm (3.47×16.9×2255 in) | 173x430x660 mm (6.8×16.9×26 in) | ||
Enclosure / Protection | steel-plastic / IP20 | |||
Mounting | Rackmount or Tower mount with same unit | |||
ENVIROMENT : | ||||
Safety Compliance | UL 1778 | |||
Electromagnetic Compatibility | EMI: FCC CFR47 Part 15, class A, ESD: IEC61000-4-2, level 4 RS: IEC61000-4-3, level 3, EFT: IEC61000-4-4, level 4, Surge: IEC61000-4-5, level 3 ANSI C62.41 (IEEE587) Category A (level 3) & B (level 1) |
|||
Ambient Temperature | 0 to +40ºC | |||
Audible Noise at 3.3 ft. | <55 dB(A), load and temperature dependent | |||
Max. Relative Humidity | 90% (non-condensing) | |||
Color | Black – RAL 9005 |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
The VH Series UPS is a more powerful solution in a compact footprint for smaller users who have relatively denser power requirements in clinics & hospitals, financial institutions, businesses, and other sites in need of an emergency power supply system. Available in rack or tower platforms and perfect for applications including but not limited to:
- Smaller data centers, IT systems, or telecom closets with relatively larger power needs
- Network switching & processing equipment
- PLC controls
- High-quality power backup system for AS-400 systems
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Compact footprint and low noise
- Easy to maneuver and install
- Suitable for installation even next to the user
- Isolation transformer design for ultimate site safety
- PDU options to suit various output configurations
Product Snapshot
Single Phase Output Voltages | 120/208/230/240V |
Wide input voltage window | Minimizes battery use, prolongs battery life |
RPA functionality for paralleling and redundancy | UPS capacity can be increased as site requirements require at no extra cost |
Internal automatic bypass switch | Continuous power supply to the load even if the UPS is overloaded |
0.8 output power factor | Prevents the need to oversize the UPS |
0.99 input power factor | |
Manual automatic bypass switch | Integrated as standard to the rear of the UPS |
GE’s unique Superior Battery Management | Ultimate protection for the UPS core component |
High efficiency 91% – 94% (model dependent) | Using ECO mode, high efficiency and low losses |
No load shutdown | Prevents deep battery discharge al low loads |
Frequency conversion 50/60Hz | Operates as a frequency converter also operating in a parallel system |
Technical Specs
GE LP-11U Series UPS (5kVA-10kVA) Technical Specifications | ||||||
---|---|---|---|---|---|---|
MODEL NUMBER | LP11U-5 | LP11U-5 (120) | LP11U-6 | LP11U-6 (120V) | LP11U-8 | LP11U-10 |
Rating (VA/W) | 5000 / 4000 | 5000 / 4000 | 6000 / 4800 | 6000 / 4800 | 8000 / 6400 | 10,000 / 8000 |
Backup Time @ 50% / 100% loads | 25 / 10 min. | 25 / 10 min. | 20 / 8 min. | 20 / 8 min. | 29 / 11 min. | 22 / 8 min. |
Enclosure (Table 1) | A | B | A | B | A | A |
Net Wgt Incl. Batteries (kg/lbs) | 134/295 | 175/386 | 134/295 | 175/386 | 175/386 | 186/410 |
Input Voltage (VAC) | ||||||
Nominal | 208 | 120 | 208 | 120 | 208 | 208 |
Range @ 100% Load (V) | 162-285 | 81-141 | 162-285 | 81-141 | 162-285 | 162-285 |
Range @ 50% Load (V) | 146-285 | 72-141 | 146-285 | 72-141 | 146-285 | 146-285 |
Input Power Factor | .99 | |||||
Input Frequency (Hz) | 40-70 | |||||
Output Power Factor | .8 | |||||
Output Voltage (VAC) (sinusoidal) | 120+208+220/230/240 User Selectable | |||||
Output Frequency (Hz) | 50/60 | |||||
Output Voltage Regulation | +/- 1% | |||||
Output THD at Linear Load | <1% | |||||
Output THD at Non-linear Load | <2% | |||||
Crest Factor Handling Capacity of a Non-linear Load | 5:1 | |||||
Overload Capability on Inverter | 110% 20 min., 130% 3.5 min., 150% 2 min. | |||||
Color | Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010) | |||||
Environment | IP20 (IEC 60529) | |||||
Operating Temperature / Humidity | 32° F – 104° F (0° C – 40° C) / 95% Non-condensing | |||||
Audible Noise | 40-50 dBA – 3.3 feet (1 meter) | |||||
Safety Classifications & Listings | UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950 | |||||
EMI | FCC Part 15 Class A / EN50091-2 | |||||
Surge Protection | IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2 | |||||
Connectivity | RS-232; programmable alarm contacts (optional); SNMP (optional) | |||||
Warranty | 24 Months |
Industries & Applications
- Hospitals, clinics, medical centers
- Government & business offices
- Police & fire emergency call centers
- Military applications
- “Lights-out” or “dark factory” manufacturing
- Large data centers or IT systems
- Critical network switching & processing equipment
- Large-scale PLC controls
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Enables you to customize UPS settings, view load and power consumption information through the graphical interactive LCD interface.
- Fully integrates with Intelligent Power Software Suite for continuous up time of servers and virtual machines.
- Provides more real power (watts) to protect more equipment and leave room for expanding IT systems.
- Delivers added runtime with extended battery modules and extends battery service life by 50% with ABM technology.
- Cuts energy usage and costs with ≥93% efficiency rating in normal mode
- Maximizes availability with extended battery runtime options, hot-swappable batteries, internal bypass and optional maintenance bypass.
- Helps save money and protect the environment through energy efficient operation (ENERGY STAR® qualified UPS).
- Split-phase models offer both 120V and 208V output without a transformer; saving vertical rack (U) space, weight and cost.
Product Snapshot
EATON 9PX UPS | |
---|---|
Power Rating | 5-11 kVA |
Voltage | 208V and 120/208V |
Frequency | 50/60 Hz |
Configuration | Rack / tower |
Technical Specs
GENERAL | |
---|---|
Configuration | Rack / Tower |
Color | Black & Silver |
Topology | Double-conversion online |
Diagnostics | Full system self test at power up |
Rail Kit | 4-post rail kit and tower pedestals included; Optional 2-post rail kit available, part number: RK2PC |
Remote emergency power off (REPO) | ROO and RPO: Rear deck emergency stop connectors (for remote on/off and power off) |
ELECTRICAL INPUT | |
Nominal Voltage | 200/208/220/230/240V |
Input Voltage Range | Full load: 176-276V, Derating: 100-276V |
Default voltage | 9PX5K and 9PX6K: 208V. 9PX6KG: 230V |
Frequency | 50/60 Hz |
Frequency | 50/60 Hz |
Frequency range | 60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz |
Input power factor | ≥.99 |
Input current distortion | <5% |
Circuit breaker | (2) 20A for L6-20R |
ELECTRICAL OUTPUT | |
Power ratings NEMA 5 kVA | 200/208/220/230/240V: 5000 VA/4500 watts |
Power ratings NEMA 6 kVA | 230/240V: 5400 watts
220V: 5100 watts 208V: 4800 watts 200V: 4600 watts |
Power ratings IEC 6 kVA | 200/208/220/230/240V: 6000 VA/5400 watts |
Nominal voltage | 208V default (200/208/220/230/240V) |
Output voltage regulation | ±1% steady-state |
Voltage THD | <2% for linear loads |
Power factor | 0.9 |
Efficiency | 93% with resistive load |
Transfer time | 0 ms |
BATTERY | |
Optional extended battery module (EBM) | 9PXEBM180RT |
Maximum number of EBMs | Add up to 4 EBMs |
Battery description | Sealed, lead-acid; maintenance free |
Battery management | ABM technology; 3-stage charging extends battery service life by 50% and provides advance warning for battery replacement |
Battery replacement | Hot-swappable internal batteries and EBMs |
Start on battery | Cold-start enabled; first cold start is always forbidden |
COMMUNICATIONS | |
User Interface | Graphical display. UPS status in a single view. |
LEDs | 4 status-indicating LEDs |
Communication ports | RS-232 (RJ45) ports; USB port as standard (HID). 6-foot RS-232 and USB cables included |
Communications card slot | Network Card-MS included |
Power management software | Eaton Intelligent Power Software Suite CD (included) |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
The EATON 9PX UPS is a more powerful solution in a compact footprint for smaller users who have relatively denser power requirements in clinics & hospitals, financial institutions, businesses, and other sites in need of an emergency power supply system. Available in rack or tower platforms and perfect for applications including but not limited to:
-
- Smaller data centers, IT systems, or telecom closets with relatively larger power needs
- Network switching & processing equipment
- PLC controls
- High-quality power backup system for AS-400 systems
Other Uninterruptible Power Supply Models
UPS Models | ||||
---|---|---|---|---|
Part Number | Power Rating | Input Plug | Output Receptacles | |
(VA/Watts) |
120/208V Output, 50/60 Hz Bundles
9PX5KTF5 | 5000 / 4500 | L6-30P** | (18) 5-20R, (2) L6-20R, (1) L6-30R |
9PX5KP1 | 5000 / 4500 | L6-30P | (6) 5-20R, (1) L6-30R, (1) L14-30R |
9PX5KP2 | 5000 / 4500 | Hardwired | Hardwired |
9PX6KSP | 5500 / 4900 | L14-30P*** | (6) 5-20R, (1) L6-30R, (1) L14-30R, Hardwired |
9PX6KTF5 | 6000 / 5400 | L6-30P** | (18) 5-20R, (2) L6-20R, (1) L6-30R |
9PX6KP1 | 6000 / 5400 | L6-30P | (6) 5-20R, (1) L6-30R, (1) L14-30R |
9PX6KP2 | 6000 / 5400 | Hardwired | Hardwired |
9PX8KSP | 8000 / 7200 | Hardwired | (1) L6-30R, (2) L14-30R, Hardwired |
9PX8KTF5 | 8000 / 7200 | Hardwired | (18) 5-20R, (2) L6-30R |
9PX10KSP | 10000 / 9000 | Hardwired | (1) L6-30R, (2) L14-30R, Hardwired |
9PX11KTF5 | 11000 / 10000 | Hardwired | (18) 5-20R, (2) L6-30R |
9PX11KTF11 | 11000 / 10000 | Hardwired | (8) 5-20R, (2) L14-30R, Hardwired |
208V Output, 50/60 Hz Bundles
9PX5K | 5000 / 4500 | L6-30P** | (2) L6-20R, (2) L6-30R, Hardwired |
9PX6K | 6000 / 5400 | L6-30P** | (2) L6-20R, (2) L6-30R, Hardwired |
9PX6KG | 6000 / 5400 | Hardwired | (8) C13, (2) C19, Hardwired |
9PX8K | 8000 / 7200 | Hardwired | (3) L6-30R, Hardwired |
9PX8KHW | 8000 / 7200 | Hardwired | Hardwired |
9PX11K | 11000 / 10000 | Hardwired | (3) L6-30R, Hardwired |
9PX11KHW | 11000 / 10000 | Hardwired | Hardwired |
TAA 9PX North American Rack Models: 208V, 50/60 Hz
9PX6KUS | 6000 / 5400 | L6-30P** | (2) L6-20R, (2) L6-30R, Hardwired |
** Terminal block with L6-30P
*** Terminal block with L14-30P
We respect your privacy and will never share your email address with anyone without your explicit permission.
The EATON 9155 UPS can serve as a complete industrial UPS system or commercial UPS system, providing premium online backup power and scalable battery runtimes for electrical engineering infrastructure in medium-sized corporate, healthcare, banking, and industrial applications.
A premium emergency power supply system that packs maximum battery runtime into a very small space, the EATON 9155 UPS can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch.
Features & Benefits
- Extraordinary power density delivers a complete emergency power supply system in less space thanks to compact design, internal batteries, and integrated static and manual bypass switches
- Optimal 0.90 output power factor reduces need to oversize your emergency power supply system
- Enhanced compatibility with upstream equipment is achieved with active PFC, an extremely efficient 0.99 input power
factor, and reduced ITHD - Proprietary Advanced Battery Management 3-stage charging system enhances backup reliability of your emergency power supply system by significantly extending battery lifetime.
- Proprietary HotSync technology enables paralleling up to four 9155 UPSs for additional capacity or redundancy in your emergency power supply system
- Ergonomically-designed and intuitive LCD interface and a wide range of connectivity options enhance the operator efficiency & safety of your emergency power supply system
- High system efficiency and power density make the EATON 9155 UPS a sustainable solution to your emergency power supply system requirements
Product Snapshot
EATON 9155 UPS | |
---|---|
Power Rating | 8-15 KVA |
Voltage | 220-230-240V |
Frequency | 50/60Hz |
Configuration | Tower |
Product Series | Powerware |
Technical Specs
POWER | |
---|---|
Ratings (kVA/Watts) | 8,10,12 and 15 kVA at 0.9 power factor |
Topology | True double-conversion online UPS |
ELECTRICAL INPUT | |
Nominal Input Voltage | 200V-240V with neutral or with optional transformer |
Input Voltage Range | -15%, +10% from nominal at 100% load without depleting battery |
Operating Frequency | 50/60 Hz (45 to 65Hz) |
Input Power Factor | P.F>0.99 typical, >0.96 frequency converter |
Input Current Distortion | 5% THD |
ELECTRICAL OUTPUT | |
Nominal Output Voltage | 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement |
Output Voltage Regulation | ±1% Static; ±5% dynamic at 100% resistive load change,<1 ms response time |
Efficiency | 90% typical |
BATTERY | |
Battery Type | 9Ah, sealed, lead-acid, maintenance-free |
Battery Runtime | See Battery Runtime Chart |
Battery Replacement | Field-replaceable |
Charger | Default is 3.4A per battery string. Charger current is configurable from 0.5A to 25A per string with an overall maximum of 34A (limited by input current) |
Start-On-Battery | Start-On-Battery Allows start of UPS without utility input |
GENERAL | |
Diagnostics | Full system self-test at startup |
UPS Bypass | Automatic on overload or UPS failure |
Parallel for Redundancy and Capacity | Yes, using Powerware Hot Sync technology |
Dimensions and Weights | See Model Selection Table |
Overload | 150% for 5 sec / 125% for 1 min (online), (Normal Operation) 110% for 10 min |
CERTIFICATIONS | |
Safety Certifications | NOM-0190SCFI-1993, UL 1778, CSA C22.2, No. 107.3; EN 5502 Class A (CISPR22 Class A) and IEC 60950; IEC 62040-1-1 |
EMC Compliance | IEC 62040-2, FCC Part 15, ICES-003, VCCI |
Quality | ISO 9001: 2000 and ISO 14001:1996 |
Markings | UL, cUL, CSA, CE and NOM-NYCE |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
A powerful solution for medium-sized banking centers, clinics & hospitals, financial institutions, and other users who require a complete industrial UPS system or commercial UPS system, the EATON 9155 UPS is also rugged & robust enough for demanding marine applications. Perfect for uses including but not limited to:
- Medium-sized data centers, IT systems, or telecom closets
- Network switching & processing equipment
- PLC controls
- High-quality power backup system for AS-400 systems
We respect your privacy and will never share your email address with anyone without your explicit permission.
[/et_pb_text][/et_pb_column][/et_pb_row][/et_pb_section]

Features & Benefits
- N+X power and logic redundancy eliminate any possible single point-of-failure
- Scalable design with 3.0 KVA power modules and batteries accommodates evolving IT environments
- Proprietary ABM technology significantly increases battery life for more uptime and fewer battery replacements
- Sophisticated software conditions incoming power without depleting the battery, thus preserving power for complete power outages
- Hot-swappable, lightweight battery modules simplify setup and service
- Ergonomically-designed and intuitive and intuitive LCD screen quickly collects information on critical operating parameters and simplifies the user experience
Product Snapshot
EATON 9170+ UPS | |
---|---|
Power Rating | 3-18 kVA |
Voltage | 200-240V |
Frequency | 50/60 Hz |
Configuration | Tower/Rackmount |
Product Series | Powerware |
Technical Specs
GENERAL | |
---|---|
Topology | True online, double-conversion |
Diagnostics | Full system self-test on power up |
UPS Bypass | Automatic on overload or UPS failure |
ELECTRICAL INPUT | |
Voltage | 208-240 VAC or 200/100, 208/120, 220/110,240/120 Vac |
Input Voltage Range | 176-276 V |
Input Power Factor | .98 |
Frequency | 50/60 Hz (± 3Hz) |
ELECTRICAL OUTPUT | |
On Utility Voltage Regulation | ±3% of nominal |
On Battery Voltage Regulation | ±3% of nominal |
Efficiency | 88% normal operation
97% High performance (optional programmable) |
Frequency Regulation | ±3 Hz online; ±0.1 Hz on battery |
COMMUNICATIONS | |
LCD Display | 4 x 20 character backlit display, programmable |
Language Support | English, French, Spanish and German |
Communication ports | RS232, (DB9) (std) |
Communication slots | 2 Slots (standard) |
SNMP capability | SNMP/Web enabled card options |
Contact Closures | Relay Card option |
Emergency Power off (EPO) | Input for external EPO |
BATTERY | |
Internal Battery Type | Sealed, lead-acid; maintenance free |
Battery Runtime | See Battery Runtimes below |
Battery Replacement | Hot-swappable |
Recharge Time | <4 hours standard |
ENVIROMENTAL & SAFETY | |
Safety Markings | UL, CUL |
EMC Markings | FCC class A |
Surge Suppression | IEEE/ANSI C62.41 |
Audible Noise | <50dBA |
Ambient Operating / Storage Temperature | 0 to 40ºC (32 to 104ºF)/-20 to 40ºC (60ºC w/o batt) -4 to 104ºF (140º F w/o batt) |
Relative Humidity | 50 to 90%, non-condensing |
REPO Port | Meets NEC code 645-11 intent and UL requirements |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
The EATON 9170+ is designed for medium-sized server farms and networks, telecom and internet service providers, clinics & hospitals, financial institutions, and other mission-critical applications requiring a high quality power backup system. Perfect for uses including but not limited to:
- Medium-sized data centers, IT systems, or telecom closets
- Network switching & processing equipment
- PLC controls
- High-quality power backup system for AS-400 systems
We respect your privacy and will never share your email address with anyone without your explicit permission.
Recent Posts
- Master HP UL (65-500kVA 3-phase) 06/17/2021
- Sentryum (10-30kVA 3-phase) 06/17/2021
- Sentinel RT (1-10kVA) 06/10/2021
- N1C Lithium Ion UPS Systems earn 2019 Sustainable Product Award 12/18/2019
- Robot Ready to Roll at Evansville Middle School 11/29/2018
Address
2949 Venture Drive, Dock 190
Janesville, WI, 53546
Hours: M-F, 8am-5pm CDT