Features & Benefits
- Ideal for hospitals, clinics, and other medical applications where power protection is critical
- High crest factor is ideal for MRI, PET, CT and other medical devices that have a high current inrush
- Unity power factor output provides 20 percent more energy than UPS systems from other manufacturers
- 100 percent generator compatible— low input-current harmonics eliminate the need for oversized generator
Technical Specs
G8000 Specifications
|
|||||||
Model #
|
T80S3K08KK 6XS2H
|
T80S3K10KK 6XS2H
|
T80S3K15KK 6XSNH
|
T80S3K22KK 6XSNH
|
T80S3K30KK 6XSNH
|
||
Input
|
Rated Output Capacity
|
80 KVA/80 KW
|
100 KVA/ 100 KW
|
150 KVA/150 KW
|
225 KVA/ 225 KW
|
300 KVA / 300 KW
|
|
Voltage
|
480 VAC (+10% to -15%)
|
||||||
Frequency
|
60 Hz (+/-5%)
|
||||||
Configuration
|
3 Phase; 3 Wire + GND
|
||||||
Input KW
|
90 KW
|
110 KW
|
165 KW
|
247 KW
|
318 KW
|
||
( 102 KW Charging)
|
(122 KW Charging)
|
(181 KW Charging)
|
(270 KW Charging)
|
(319 KW Charging)
|
|||
Power Factor
|
> 0.99 PF Lagging
|
||||||
Walk-In Function
|
EEPROM Upgrade
|
||||||
Maximum Input Current
|
108 A Normal
|
135 A Normal
|
200 A Normal
|
303 A Normal
|
396 A Normal
|
||
(125 A Charging)
|
(150 A Charging)
|
(222 A Charging)
|
(338 A Charging)
|
(401 A Charging)
|
|||
Reflected THD
|
< 5% Maximum @ 100% Load
|
||||||
6% Maximum @ 25% Load
|
|||||||
Bypass
|
Configuration
|
Three-Phase; Four-Wire + Ground
|
|||||
Voltage
|
480/277V (±10%)
|
||||||
Frequency
|
60 Hz (±5%)
|
||||||
Bypass Overload Capacity
|
1000% for One Cycle, 500% for Two Cycles
|
||||||
Battery Backup
|
Number of Cells
|
180
|
|||||
Type
|
Lead Acid (Contact Factory for Alternative Options)
|
||||||
DC Nominal
|
360 V
|
||||||
DC Minimum
|
288 V
|
||||||
Float Charge
|
405 V
|
||||||
Ripple Current (without batteries)
|
AC Ripple on DC Bus: < 0.2% of DC Voltage
|
||||||
Back-up Time
|
Application Specific
|
||||||
Max DC Charging Current
|
30 A
|
30 A
|
30 A
|
30 A
|
30 A
|
||
Max Discharge
|
305
|
375
|
566
|
840
|
1120
|
||
Battery Capacity Required for Full Load Output
|
88 KWB
|
108 KWB
|
163 KWB
|
245 KWB
|
323 KWB
|
||
Output
|
Voltage
|
480Y/277V
|
|||||
Configuration
|
Three-Phase; Four-Wire + Ground
|
||||||
Voltage Regulation
|
±1% for 0 to 100%Balanced and Unbalanced Loads
|
||||||
Voltage Adjustment Range
|
±5% (In Increments of 1V)
|
||||||
Voltage Unbalance
|
±3% for 100% Linear Loads ±5% for 100% Non-Linear Loads
|
||||||
Crest Factor
|
2
|
||||||
Transient Voltage Response
|
±2% Maximum with a 100% Step Loads (Without Utilizing Batteries)
|
||||||
±1.5% Maximum with Loss/Return AC Input
|
|||||||
±2% Maximum When Load Transfers To/From Bypass
|
|||||||
Transient recovery time
|
< 50 ms
|
||||||
Frequency
|
60 Hz
|
||||||
Frequency Synchronous Range
|
±0.5 Hz, ±1 Hz, + 1.5Hz (Selectable)
|
||||||
Frequency Slew Rate
|
1 Hz/Sec
|
||||||
Frequency Regulation
|
±0.01% in free running mode
|
||||||
Current
|
96 A
|
120 A
|
180 A
|
271 A
|
361 A
|
||
Power Factor
|
1.0 PF Lagging: 32 – 86 °F (0 – 30 °C) 0.8 PF Lagging: 86 – 104 °F (30 – 40 °C)
|
||||||
Overload Capacity
|
125% for 10 Minutes, 150% for 60 Seconds
|
||||||
Voltage THD
|
< 3% Max with 100% Linear Load/5% Max with 100% Non-Linear Load
|
||||||
Reliability
|
MTBF
|
200,000 Hours
|
|||||
Efficiency
|
@ 25% Load
|
83.9%
|
86.4%
|
89.6%
|
87.9%
|
88.8%
|
|
@ 50% Load
|
85.3%
|
90.1%
|
91.7%
|
91.0%
|
91.7%
|
||
@ 75% Load
|
90.0%
|
91.2%
|
92.3%
|
92.3%
|
92.7%
|
||
@ 100% Load
|
90.6%
|
91.0%
|
93.0%
|
91.9%
|
92.0%
|
||
Environment
|
Cooling
|
Forced Air
|
|||||
Paint Color
|
Sherwin Williams HHT2-7055, 079 Beige Texture
|
||||||
Weight
|
1390lb. (630 kg)
|
1740 lb. (789 kg)
|
2467 lb. (1119kg)
|
2980 lb. (1352 kg)
|
4575 lb. (2075 kg)
|
||
Weight (Shipping)
|
1440 lb. (653 kg)
|
1790 lb. (812 kg)
|
2556 lb. (1159 kg)
|
3069 lb. (1392 kg)
|
4725 lb. (2143 kg)
|
||
Floor Loading
|
171 Lbs/ft2 (1037 kg/m2)
|
214 Lbs/ft2 (1299 kg/m2)
|
203 Lbs/ft2 (991 kg/m2)
|
245 Lbs/ft2 (1196 kg/m2)
|
255 Lbs/ft2 (1245 kg/m2)
|
||
Dimension – Width
|
36.8 in. (935 mm)
|
55.1 in. (1400 mm)
|
76.8 in. (1951 mm)
|
||||
Depth
|
32.5 in. (826 mm)
|
31.8 in. (808 mm)
|
35.7 in. (907 mm)
|
||||
Height
|
79.2 in. (2012 mm)
|
79.4 in. (2017 mm)
|
|||||
Power Cable Access
|
Bottom Access
|
Top or Bottom Access
|
Top Access
|
||||
Clearance Required
|
Top: 15.75″ (400 mm)
|
||||||
Front: 43 7/16″ (1100 mm)
|
|||||||
Back/Left/Right Sides: Zero
|
|||||||
Enclosure
|
NEMA 1
|
||||||
Heat Loss to be Removed @ Full Load
|
28,387 BTUs/Hour
|
34,222 BTUs/Hour
|
44,506 BTUs/Hour
|
68,240 BTUs/Hour
|
85,300 BTUs/Hour
|
||
Audible Noise
|
65 DBA @ 1m Typical
|
68 DBA @ 1 m Typical
|
72 DBA @ 1 m Typical
|
||||
Operating Temperature
|
32? to 86?F (0? to 30?C) for 1.0 PF 32? to 104?F (0? to 40?C) for 0.8 PF
|
||||||
Operating Humidity
|
30% to 90% Non-Condensing
|
||||||
Operating Altitude
|
3200 Feet (1000 m)
|
||||||
Listings/Standards
|
UL 1778; UL 17025, cUL 22.2, No. 107.1; ANSI C62.41 (IEEE 587 Cat B) NFPA 70; OSHA; ISO 9001; IEC298 IP20
|
||||||
Monitoring
|
Warranty
|
Three Years Parts and Labor
|
|||||
Dry Contacts Included
|
Yes for Input and Output Signals
|
||||||
RS232 Port
|
Included
|
||||||
Intelligent Monitoring (Optional)
|
SNMP; Modbus RTU; Modbus TCP; BACNET, METASYS
|
||||||
Display
|
LCD Touch-Panel for Local Monitoring, Operation, and Control
|
||||||
EPO
|
Emergency Power Off
|
Included
|
|||||
Configuration
|
Input Conv.
|
6-Diode Bridge Rectifier
|
|||||
Battery Cct
|
IGBT Chopper
|
||||||
Out. Inv.
|
IGBT Converter with PWM
|
Industries & Applications
- Hospitals, clinics, and other medical facilities
- “Lights-out” or “dark factory” manufacturing
- Large data centers or IT systems
- Critical network switching & processing equipment
- Large-scale PLC controls