Ultra efficient and budget-friendly Riello UPS Master HP UL 3-phase 480V UPS Systems.
Truly the next generation of industrial UPS systems and commercial UPS systems, the Toshiba 4400 Series is a double-conversion, all insulated-gate bipolar transistor uninterruptible power system that features a digitally-controlled IGBT input rectifier, intelligent low harmonic pulse-width modulation of the output, and state-of-the-art electronic battery isolation circuitry.
Total front-access design requires zero rear-clearance and includes convenient features such as top, bottom, and/or side cable entry, standard sized air filter provisions, and lockable keyed doors. Small footprint and intuitive local touchscreen interface make it versatile and user-friendly, and it can be customized to your specific needs with such options as internal battery backup, internal transformers for specific voltage applications, and remote monitoring with the Toshiba RemotEye® 4 multi-protocol UPS.
Features & Benefits
- Double-conversion, all insulated-gate bipolar transistor uninterruptible power system
- Digitally-controlled IGBT input rectifier
- Intelligent low harmonic pulse-width modulation of the output
- State-of-the-art electronic battery isolation circuitry
- Total front-access design requires zero rear-clearance
- Top, bottom, and/or side cable entry, standard sized air filter provisions, and lockable keyed doors
- Small footprint for ease of installation
- Intuitive local touchscreen interface make it versatile and user-friendly
- Can be customized with internal battery backup, internal transformers for specific voltage applications, and remote monitoring with the Toshiba RemotEye® 4 multi-protocol UPS.
Technical Specs
MODEL | Model Number | 4400X3X150XA | 4400X3X200XA | 4400X3X250XA | 4400X3X300XA | 4400X3X500XA | 4400X3X800XA |
Capacity | 15 kVA (13.5 kW) | 20 kVA (18 kW) | 25 kVA (22.5 kW) | 30 kVA (27 kW) | 50 kVA (45 kW) | 80 kVA (72 kW) | |
Topology | True On-Line, Double-Conversion, All-IGBT Technology | ||||||
INPUT | Voltage (Standard) | 208/120V Three-phase, Four-Wire + Ground Input* | |||||
Voltage Range | -15% to +10% (Without Using Battery) | ||||||
Power Factor | > 0.98 | ||||||
Current THD | < 5% at 100% Load | ||||||
Frequency | 50 ±5 Hz; 60 ±5 Hz | ||||||
OUTPUT | Voltage (Standard) | 208/120 V: Three-Phase, Four-Wire + Ground** | |||||
Frequency | 50/60 Hz, ±0.1% Auto-Sensing Standard. (50/60Hz Selectable, for use as Frequency Converter) |
||||||
Voltage Regulation | ±2.0% | ||||||
Power Factor | 0.9 Lagging | ||||||
Overload | Inverter: 125% for 90 Seconds, 150% for 30 Seconds Bypass: 125% for 10 Minutes, 1000% for 10 Milliseconds |
||||||
BATTERY | DC Link | 288 VDC | |||||
Ripple Voltage | < 0.5% DC | ||||||
ENVIRONMENT | Temperature Range | 32° to 104°F (0° to 40°C) | |||||
Relative Humidity | 5% to 95% Non-Condensing | ||||||
Heat Rejection | 4556 BTUs/Hour |
6074 BTUs/Hour |
7395 BTUs/Hour |
9111 BTUs/Hour |
15,186 BTUs/Hour |
24,297 BTUs/Hour |
|
Full-Load Efficiency | 91.0% | ||||||
25% Load Efficiency | 88.8% | ||||||
Altitude | 3300 ft. (1000 m) Maximum Without Derating | ||||||
Air Filtration | Airflow Front to Top with Provisions for Front-Located Air Filters |
||||||
DIMENSIONS | Dimensions | 20.12″ (W) x 37.4″ (D) x 65.06″ (H) (511mm x 950mm x 1653mm) |
32.1″ (W) x 31.8″ (D) x 73.6″ (H) (816mm x 807mm x 1870mm) |
||||
Weight*** | 720 lbs. (326 kg) | 1350 lbs. (612 kg) | 1500 lbs. (680 kg) | ||||
COLOR | O’Brien Black (Textured Powder Coat) | ||||||
MONITORING | Touchscreen Operator Interface, UPS Status N/O Dry Contacts, RS232C Interface (Optional RemotEye® 4 Intelligent Monitoring System) |
||||||
OPTIONS | Internal Batteries, Transformers, Dual-Input Feed, RemotEye® Intelligent Monitoring System, Remote Status Alarm Panel, Air Filters |
||||||
STANDARDS | UL 1778, CUL, ISO9001, ISO14001:2004, ANSI C62.41 (IEEE 587), NEMA/PET-1993, CE, IBC, & CBC (OSHPD) |
||||||
WARRANTY | 3-Year On-Site Warranty; 5-Year Warranty Available; See Toshiba Warranty Policy for Full Details |
||||||
SERVICE | 24-Hour, 365-Day Technical Support: 1-877-867-8773 | ||||||
* Isolation and Auto Transformer Options for Input Voltage Conversion ** Auto Transformer Options for Output Voltage Conversion *** Unit Weight Not Including Internal Battery and Transformers Specifications subject to change without notice. |
Industries & Applications
- Critical network switching & processing equipment
- Large-scale PLC controls
- Medium-to-larger data centers
- Hospital applications such as MRI, CT, or PET scanning equipment
- Financial Institutions
- Industrial applications
- Pharmacological manufacturing
We respect your privacy and will never share your email address with anyone without your explicit permission.
Designed specifically as an industrial UPS system for the specific needs of the IT industry, the 4300 Series boasts one of the largest input voltage/frequency windows in the industry, which extends useful battery life. Features include true online double-conversion, an input power factor better than 98 percent, and input current THD less than 3 percent.
Frontend IGBT design allows the 4200FA to work optimally from zero to 100 percent load with less than 3 percent THD on the input, allowing for generator single-sizing. Optional matching battery cabinet and maintenance bypass cabinet allow for sixty combinations of three-phase/three-wire and three-phase/four-wire input/output voltages. Comes with a standard three year warranty.
Features & Benefits
- True online double-conversion
- “Line up and match” ancillary equipment [transformer, battery, and MBS cabinets]
- Zero rear-clearance required
- Complete front-access design with top, front, and side entry
- Local touch-screen interface
- 90 percent output power factor
- Input Power Factor > 98 percent
- Input Current < 3 percent
Technical Specs
4300 Series
|
|||
Model | Model Number | 4310F3F300XAXX | 4310F3F500XAXX |
Capacity | 30 KVA/27 KW | 50 KVA/ 45 KW | |
Topology | True On-Line, Double Conversion, & All IGBT Technology | ||
INPUT | Voltage | 208/120 V: Three-Phase, Four-Wire + Ground/Bypass Input; 208/120 V: Three-Phase, Four-Wire + Ground | |
Voltage Range | 208 V, -20% to +15% (166 to 239 V Without Using Battery) | ||
Power Factor | > 0.99 | ||
Current THD | < 3% at 100% Load | ||
Frequency | 50 ±5 Hz; 60 ±5 Hz | ||
OUTPUT | Voltage | 208/120 V: Three-Phase, Four-Wire + Ground | |
Frequency | 50/60 Hz, ±0.1% (Can be Used as Frequency Converter) | ||
Voltage Regulation | ±1.0% (0.5% Typical) | ||
Power Factor | 0.9 Lagging | ||
Overload | Inverter: 125% for 90 Seconds, 150% for 30 Seconds Bypass: 125% for 10 Minutes, 1000% for 10 Milliseconds | ||
BATTERY | DC Link | 288 VDC | |
Ripple Voltage | < 0.5% DC | ||
ENVIRONMENT | Temperature Range | 32° to 104°F (0° to 40°C) | |
Relative Humidity | 5% to 95% Non-Condensing | ||
Heat Rejection | 8153 BTUs/Hour | 15,019 BTUs/Hour | |
Full-Load Efficiency | 91.90% | 91.10% | |
25% Load Efficiency | 88.00% | 88.80% | |
Altitude | 6600 ft. (2000 m) Maximum Without Derating | ||
Audible Noise | < 65 dBA at 1m Air Filtration; Standard Front Air Filter | ||
DIMENSIONS | Dimensions | 22.1 x 31.6 x 73.6 in. (73.7 in. (H) with Fan Cage) | |
Weight | 788 lbs. | 867 lbs. | |
COLOR | O’Brien Black (Textured Powder Coat) | ||
COMMUNICATION OPTIONS | RemotEye® III & Ethernet/SNMP | ||
OPTIONS | Dual-Input Feed | ||
STANDARDS | UL 1778, ULC, CE, FCC Class A, ISO9001, ISO14001, ANSI C62.41 (IEEE 587), & NEMA PE 1-1993 | ||
WARRANTY | Three-Years On-Site Warranty; Five-Years Available; See Toshiba Warranty Policy for Full Details | ||
SERVICE | 24-Hour, 365-Day Technical Support: 1-877-867-8773 |
Industries & Applications
- Critical network switching & processing equipment
- Large-scale PLC controls
- Medium-to-larger data centers
- Financial Institutions
- Industrial applications
We respect your privacy and will never share your email address with anyone without your explicit permission.
Noted for its versatility, and offering the largest input voltage/frequency window in the industry, the 4200FA Series is designed to be a high-performance state-of-the-art commercial or industrial UPS system suitable for use across a wide breadth of industrial UPS system applications.
Features include true online double-conversion, an input power factor better than 98 percent, and input current THD less than 3 percent. Frontend IGBT design allows the 4200FA to work optimally from zero to 100 percent load with less than 3 percent THD on the input, allowing for generator single-sizing. Proprietary technology lengthens battery life. The CT models feature internal batteries and maintenance bypass— without the need for additional cabinets. Comes with a standard three year warranty.
Features & Benefits
- Largest input voltage/frequency window in the industry
- Suitable for use across a wide breadth of industries and applications
- True online double-conversion
- Input power factor better than 98 percent
- Input current THD less than 3 percent
- Frontend IGBT design works optimally from zero to 100 percent load with less than 3 percent THD on the input—allowing for generator single-sizing
- Proprietary technology lengthens battery life
- Three year warranty
Technical Specs
4200FA CT Standard Specifications
|
|||||
Model Number
|
T42F3F150XAMBN
|
T42F3F250XAMBN
|
T42F3F300XAMBN
|
T42F3F500XAMBN
|
|
Capacity | kVA/kW |
15/12
|
25/20
|
30/24
|
50/40
|
Topology |
True On-line, Double Conversion, IGBT Pwm, with Active
Input Power Factor Correction |
||||
Input | Voltage |
208/120 V, 3 Phase, 4 w + Gnd
|
|||
Voltage Range |
+10% to -30%; +20% to -30% online (without utilizing
battery) |
||||
Power Factor |
Greater than 0.99
|
||||
Current THD |
Less than 3%
|
||||
Frequency |
50/60 Hz (Range 45 to 65 Hz)
|
||||
Current Limit |
115% Maximum
|
||||
Output | Voltage |
208/120 V, 3-Phase, 4 w + Gnd
|
|||
Frequency |
50/60 Hz � 0.01% (Can be Used as a Frequency Converter)
|
||||
Voltage Regulation |
< 1% Balanced, 100% Load Step / < 2% Unbalanced,
100% Load Step |
||||
Overload (Inverter) |
125% for 90 Seconds, 150% for 30 Seconds
|
||||
Overload (Bypass) |
125% for 10 Minutes, 1000% for 10 milliseconds
|
||||
Battery | Time (Full / Half Load) |
9/26 Minutes
|
4/13 Minutes
|
3/10 Minutes
|
4.5/14 Minutes
|
DC Link |
288 VDC
|
||||
Ripple Voltage |
< 0.5% DC
|
||||
Environment | Temperature Range |
0 to 40� C (Operating) / -20 to +50� C (Storage)
|
|||
Relative Humidity |
0 to 95% Non-Condensing
|
||||
Heat Rejection |
8,988 BTUs
|
12,043 BTUs
|
14,451 BTUs
|
18,611 BTUs
|
|
Efficiency |
82% AC-AC
86% DC-AC |
85% AC-AC
87% DC-AC |
88% AC-AC
89% DC-AC |
89% AC-AC
88% DC-AC |
|
Dimensions | Dimensions (L x D x H) |
20″ x 36.3″ x 59.7″
|
35.4″ x 37.6″ x 59.8″
|
||
Weight (lb) |
900
|
910
|
915
|
2548
|
|
Altitude |
6600 ft (2000 m)(Maximum without Derating)
|
||||
Audible Noise |
< 60 dBA at 1 m
|
< 65 dBA at 1 m
|
|||
Features |
Internal Make-Before-Break Maintenance Bypass Switch,
RS232 and Dry Contact Interface |
||||
Standards |
UL 1778, cUL, NEC, ISO9001, ISO14001, ANSI C62.41 (IEEE
587), NEMA PE1-1993 |
||||
Warranty |
(See Toshiba Warranty Policy for Full Details.)
|
||||
Service |
7 x 24 Technical Support 1-877-867-8773 (1-UPS-TOS-UPS3)
|
||||
rev 6/2010 |
Industries & Applications
- Hospitals, clinics, and other medical facilities
- “Lights-out” or “dark factory” manufacturing
- Critical network switching & processing equipment
- Large-scale PLC controls
- Medium-to-larger data centers
- Financial Institutions
- Industrial applications
- Pharmacological manufacturing
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Ideal for hospitals, clinics, and other medical applications where power protection is critical
- High crest factor is ideal for MRI, PET, CT and other medical devices that have a high current inrush
- Unity power factor output provides 20 percent more energy than UPS systems from other manufacturers
- 100 percent generator compatible— low input-current harmonics eliminate the need for oversized generator
Technical Specs
G8000 Specifications
|
|||||||
Model #
|
T80S3K08KK 6XS2H
|
T80S3K10KK 6XS2H
|
T80S3K15KK 6XSNH
|
T80S3K22KK 6XSNH
|
T80S3K30KK 6XSNH
|
||
Input
|
Rated Output Capacity
|
80 KVA/80 KW
|
100 KVA/ 100 KW
|
150 KVA/150 KW
|
225 KVA/ 225 KW
|
300 KVA / 300 KW
|
|
Voltage
|
480 VAC (+10% to -15%)
|
||||||
Frequency
|
60 Hz (+/-5%)
|
||||||
Configuration
|
3 Phase; 3 Wire + GND
|
||||||
Input KW
|
90 KW
|
110 KW
|
165 KW
|
247 KW
|
318 KW
|
||
( 102 KW Charging)
|
(122 KW Charging)
|
(181 KW Charging)
|
(270 KW Charging)
|
(319 KW Charging)
|
|||
Power Factor
|
> 0.99 PF Lagging
|
||||||
Walk-In Function
|
EEPROM Upgrade
|
||||||
Maximum Input Current
|
108 A Normal
|
135 A Normal
|
200 A Normal
|
303 A Normal
|
396 A Normal
|
||
(125 A Charging)
|
(150 A Charging)
|
(222 A Charging)
|
(338 A Charging)
|
(401 A Charging)
|
|||
Reflected THD
|
< 5% Maximum @ 100% Load
|
||||||
6% Maximum @ 25% Load
|
|||||||
Bypass
|
Configuration
|
Three-Phase; Four-Wire + Ground
|
|||||
Voltage
|
480/277V (±10%)
|
||||||
Frequency
|
60 Hz (±5%)
|
||||||
Bypass Overload Capacity
|
1000% for One Cycle, 500% for Two Cycles
|
||||||
Battery Backup
|
Number of Cells
|
180
|
|||||
Type
|
Lead Acid (Contact Factory for Alternative Options)
|
||||||
DC Nominal
|
360 V
|
||||||
DC Minimum
|
288 V
|
||||||
Float Charge
|
405 V
|
||||||
Ripple Current (without batteries)
|
AC Ripple on DC Bus: < 0.2% of DC Voltage
|
||||||
Back-up Time
|
Application Specific
|
||||||
Max DC Charging Current
|
30 A
|
30 A
|
30 A
|
30 A
|
30 A
|
||
Max Discharge
|
305
|
375
|
566
|
840
|
1120
|
||
Battery Capacity Required for Full Load Output
|
88 KWB
|
108 KWB
|
163 KWB
|
245 KWB
|
323 KWB
|
||
Output
|
Voltage
|
480Y/277V
|
|||||
Configuration
|
Three-Phase; Four-Wire + Ground
|
||||||
Voltage Regulation
|
±1% for 0 to 100%Balanced and Unbalanced Loads
|
||||||
Voltage Adjustment Range
|
±5% (In Increments of 1V)
|
||||||
Voltage Unbalance
|
±3% for 100% Linear Loads ±5% for 100% Non-Linear Loads
|
||||||
Crest Factor
|
2
|
||||||
Transient Voltage Response
|
±2% Maximum with a 100% Step Loads (Without Utilizing Batteries)
|
||||||
±1.5% Maximum with Loss/Return AC Input
|
|||||||
±2% Maximum When Load Transfers To/From Bypass
|
|||||||
Transient recovery time
|
< 50 ms
|
||||||
Frequency
|
60 Hz
|
||||||
Frequency Synchronous Range
|
±0.5 Hz, ±1 Hz, + 1.5Hz (Selectable)
|
||||||
Frequency Slew Rate
|
1 Hz/Sec
|
||||||
Frequency Regulation
|
±0.01% in free running mode
|
||||||
Current
|
96 A
|
120 A
|
180 A
|
271 A
|
361 A
|
||
Power Factor
|
1.0 PF Lagging: 32 – 86 °F (0 – 30 °C) 0.8 PF Lagging: 86 – 104 °F (30 – 40 °C)
|
||||||
Overload Capacity
|
125% for 10 Minutes, 150% for 60 Seconds
|
||||||
Voltage THD
|
< 3% Max with 100% Linear Load/5% Max with 100% Non-Linear Load
|
||||||
Reliability
|
MTBF
|
200,000 Hours
|
|||||
Efficiency
|
@ 25% Load
|
83.9%
|
86.4%
|
89.6%
|
87.9%
|
88.8%
|
|
@ 50% Load
|
85.3%
|
90.1%
|
91.7%
|
91.0%
|
91.7%
|
||
@ 75% Load
|
90.0%
|
91.2%
|
92.3%
|
92.3%
|
92.7%
|
||
@ 100% Load
|
90.6%
|
91.0%
|
93.0%
|
91.9%
|
92.0%
|
||
Environment
|
Cooling
|
Forced Air
|
|||||
Paint Color
|
Sherwin Williams HHT2-7055, 079 Beige Texture
|
||||||
Weight
|
1390lb. (630 kg)
|
1740 lb. (789 kg)
|
2467 lb. (1119kg)
|
2980 lb. (1352 kg)
|
4575 lb. (2075 kg)
|
||
Weight (Shipping)
|
1440 lb. (653 kg)
|
1790 lb. (812 kg)
|
2556 lb. (1159 kg)
|
3069 lb. (1392 kg)
|
4725 lb. (2143 kg)
|
||
Floor Loading
|
171 Lbs/ft2 (1037 kg/m2)
|
214 Lbs/ft2 (1299 kg/m2)
|
203 Lbs/ft2 (991 kg/m2)
|
245 Lbs/ft2 (1196 kg/m2)
|
255 Lbs/ft2 (1245 kg/m2)
|
||
Dimension – Width
|
36.8 in. (935 mm)
|
55.1 in. (1400 mm)
|
76.8 in. (1951 mm)
|
||||
Depth
|
32.5 in. (826 mm)
|
31.8 in. (808 mm)
|
35.7 in. (907 mm)
|
||||
Height
|
79.2 in. (2012 mm)
|
79.4 in. (2017 mm)
|
|||||
Power Cable Access
|
Bottom Access
|
Top or Bottom Access
|
Top Access
|
||||
Clearance Required
|
Top: 15.75″ (400 mm)
|
||||||
Front: 43 7/16″ (1100 mm)
|
|||||||
Back/Left/Right Sides: Zero
|
|||||||
Enclosure
|
NEMA 1
|
||||||
Heat Loss to be Removed @ Full Load
|
28,387 BTUs/Hour
|
34,222 BTUs/Hour
|
44,506 BTUs/Hour
|
68,240 BTUs/Hour
|
85,300 BTUs/Hour
|
||
Audible Noise
|
65 DBA @ 1m Typical
|
68 DBA @ 1 m Typical
|
72 DBA @ 1 m Typical
|
||||
Operating Temperature
|
32? to 86?F (0? to 30?C) for 1.0 PF 32? to 104?F (0? to 40?C) for 0.8 PF
|
||||||
Operating Humidity
|
30% to 90% Non-Condensing
|
||||||
Operating Altitude
|
3200 Feet (1000 m)
|
||||||
Listings/Standards
|
UL 1778; UL 17025, cUL 22.2, No. 107.1; ANSI C62.41 (IEEE 587 Cat B) NFPA 70; OSHA; ISO 9001; IEC298 IP20
|
||||||
Monitoring
|
Warranty
|
Three Years Parts and Labor
|
|||||
Dry Contacts Included
|
Yes for Input and Output Signals
|
||||||
RS232 Port
|
Included
|
||||||
Intelligent Monitoring (Optional)
|
SNMP; Modbus RTU; Modbus TCP; BACNET, METASYS
|
||||||
Display
|
LCD Touch-Panel for Local Monitoring, Operation, and Control
|
||||||
EPO
|
Emergency Power Off
|
Included
|
|||||
Configuration
|
Input Conv.
|
6-Diode Bridge Rectifier
|
|||||
Battery Cct
|
IGBT Chopper
|
||||||
Out. Inv.
|
IGBT Converter with PWM
|
Industries & Applications
- Hospitals, clinics, and other medical facilities
- “Lights-out” or “dark factory” manufacturing
- Large data centers or IT systems
- Critical network switching & processing equipment
- Large-scale PLC controls
We respect your privacy and will never share your email address with anyone without your explicit permission.
Boasting efficiencies that are 10-to20 percent beyond current industry standards, the G9000 Series is excellent for N+1 parallel systems where loads are typically 30-to 40 percent. Designed for either standalone or parallel use, the G9000 Series allows you to configure as many of eight units— without requiring the use of a special switchgear cabinet.
Toshiba proprietary technology and double-conversion topology provide AC/DC/AC efficiencies of up to 97 percent at loads from 50 to 100 percent. In fact, even at 20 percent loading, the efficiency remains greater than 94 percent. Available in capacities of 100, 160, 225, 300, 500, 750, and 1000kVA, the G9000 Series comes with an industry-leading three-year onsite warranty.
Features & Benefits
- Efficiencies 10-to20 percent beyond current industry standards
- Excellent for N+1 parallel systems where loads are typically 30-to 40 percent
- Designed for either standalone or parallel use
- Configure as many of eight units— without requiring the use of a special switchgear cabinet
- Double-conversion topology provides AC/DC/AC efficiencies of up to 97 percent at loads from 50 to 100 percent.
- Efficiency remains greater than 94 percent even at as low as 20-percent loading
- Available in capacities of 100, 160, 225, 300, 500, 750, and 1000kVA
- Comes with an industry-leading three-year onsite warranty
Technical Specs
G9000 Standard Specifications
|
|||||||
MODEL NUMBER
|
T90S3S10KS6XSN
|
T90S3S16KS6XSN
|
T90S3S22KS6XSN
|
T90S3S30KS6XSN
|
T90S3S50KS6XSN
|
T90S3S75KS6XSN
|
T90S3S01MS6XSN
|
Capacity (KVA/KW)
|
100/90
|
160/144
|
225/202.5
|
300/300
|
500/500
|
750/750
|
1000/1000
|
Topology | True On-Line, Double Conversion, Advanced Multi-Level IGBT Technology | ||||||
INPUT | |||||||
Voltage | 480 V, Three-Phase, Three-Wire + Ground/Bypass Input; 480 V, Three-Phase, Three-Wire + Ground | ||||||
Voltage Range | 480 V, -20% to +15% (384 to 552 V Without Utilizing Battery) | ||||||
Power Factor | Greater than 0.99 | ||||||
Current THD | < 3% at 100% Load (No Input Filter Required) | ||||||
Frequency | 60 Hz (±10%) | ||||||
OUTPUT | |||||||
Voltage | 480 V, Three-Phase, Three-Wire + Ground | ||||||
Frequency | 60 Hz, ±0.01% (In Free-Running Mode) | ||||||
Voltage Regulation | ±1.0% (0.5% Typical) | ||||||
Power Factor | 0.9 Lagging | 1.0 (Unity) | |||||
Voltage THD | < 2% for Linear Load; < 5% for Non-Linear Load | ||||||
Overload (Inverter) | 125% for 2 Minutes; 150% for 60 Seconds | 125% for 10 Minutes; 150% for 60 Seconds | |||||
Overload (Bypass) | 1000% for One Cycle | 500% for One Cycle | |||||
BATTERY | |||||||
DC Link | 480 VDC Nominal | ||||||
ENVIRONMENT | |||||||
Temperature Range | 32° to 104°F (0° to 40°C) | ||||||
Relative Humidity | 5% to 95% Non-Condensing | ||||||
Heat Rejection | 13.5 kBTU/Hour | 17.8 kBTU/Hour | 25.1 kBTU/Hour | 31.7 kBTU/Hour | 52.8 kBTU/Hour | 79.2 kBTU/Hour | 112.8 kBTU/Hour |
Efficiency (Full Load) | 95.80% | 96.50% | 96.50% | 97.00% | 97.00% | 97.00% | 96.80% |
Efficiency (20% Load) | 92.50% | 94.70% | 94.90% | 94.40% | 94.80% | 95.50% | 95.50% |
Altitude | 7380 Feet Maximum Without Derating (2250 Meters) | 6500 Ft. max | |||||
Audible Noise | 70 DBA at 1 Meter | 73 DBA at 1 Meter | |||||
DIMENSIONS | |||||||
Dimensions (W x D x H) | 27.6 x 32.8 x 80.6 in. | 35.4 x 32.8 x 80.6 in. | 51.2 x 32.7 x 80.7 in | 70.9 x 32.7 x 80.7 in. | 90.6 x 32.7 x 80.7 in. | 118.2 x 35.5 x 80.7 in. | |
700 x 832 x 2047 mm | 900 x 832 x 2047 mm | 1300 x 832 x 2050 mm | 1800 x 832 x 2050 mm | 2300 x 832 x 2050 mm | 3003 x 902 x 2050 mm | ||
Weight | 855 lbs. | 1160 lbs. | 1230 lbs. | 2260 lbs. | 3360 lbs. | 4250 lbs. | 6613 lbs. |
388 kg | 526 kg | 558 kg | 1025 kg | 1525 kg | 1928 kg | 3000 kg | |
FEATURES | |||||||
Digital Signal Processor (DSP) Control, Fully Digital IGBT Converter & Inverter, High Efficiency Over Wide Load Range, | |||||||
Transformer-Less Design, N+1 & N+N (Up to Eight in Parallel) Capability, Dual-Input Feed, Electronic Battery Isolation, | |||||||
RS232 and Dry Contact Interface, Small Footprint, & Lightweight Design | |||||||
STANDARDS | |||||||
UL 1778 and UL-C Listed, ISO9001, ISO14001, ANSI C62.41(IEEE 587), FCC Class A, Article 47, Part 15.B | UL 1778 and UL-C Listed, ISO9001, ISO14001, ANSI C62.41(IEEE 587), IEC 62040-2 Cat.3 | ||||||
WARRANTY | |||||||
Three Years Onsite (Optional Two-Year Extended Warranty); See Toshiba Warranty Policy for Full Details | |||||||
SERVICE | |||||||
24-Hour, 365-Day Technical Support 877-226-3311 |
Industries & Applications
- Police & fire emergency call centers
- Military applications
- “Lights-out” or “dark factory” manufacturing
- Large data centers or IT systems
- Critical network switching & processing equipment
- Large-scale PLC controls
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Redundant parallel architecture for ultimate reliability
- Up to 99% operating efficiency—with written efficiency guarantees thereto
- Proprietary eBoost technology minimizes efficiency losses
- Line conditioning & voltage regulation via patented design bypass inductor
- Proprietary technology to lengthen battery life
- Top or bottom cable access
- Matching battery and maintenance bypass cabinet for easy configuration
- Full front-maintainability design
- Scalable to meet future growth needs
- Can be paralleled up to six modules
Technical Specs (10-150kVA)
GE SG Series 10-150 kVA high efficiency UPS Systems | |||||||||
---|---|---|---|---|---|---|---|---|---|
TOPOLOGY | True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass | ||||||||
TECHNOLOGY | Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency | ||||||||
OPERATING MODES | True on-line double conversion, automatic bypass, frequency converter, RPA™ up to eight (8) units | ||||||||
OUTPUT POWER RATING kVA | 10* | 20* | 30 | 40 | 50 | 80 | 100 | 120 | 150 |
Output Power Factor | .8 | ||||||||
Output Power Rating (kW) | 8 | 16 | 24 | 32 | 40 | 64 | 80 | 96 | 120 |
Dimensions W x D x H (inches) | 27 x 32 x 71 | 32 x 32 x 71 | 47 x 32 x 71 | ||||||
Weight w/o Batteries (lbs) | 735 | 736 | 970 | 1147 | 1257 | 1489 | 1929 | 2006 | 2160 |
Noise Level dB(A) | 60 | 63 | 65 | ||||||
Input Voltage (VAC) | 480V, 3 Phase, 4 Wire w/ground (grounded WYE) | ||||||||
Input Voltage Range | -20% to +15% (without battery discharge) | ||||||||
Input Frequency | 60Hz +/-10% | ||||||||
Input Power Factor | .8 PF (.93 with input filter) (.93 with 5th filter) | ||||||||
Output Voltage (sinusoidal) (VAC) | 480V, 3 Phase, 4 Wire w/ground | ||||||||
Output Frequency | 60Hz +/-10% | ||||||||
Output THD at Linear Load | <2% | ||||||||
Output THD at Non-linear Load | <3% | ||||||||
Crest Factor | 3:1 | ||||||||
Overload Capability on Inverter | 125% @ 10 min., 150% @ 1 min. | ||||||||
Overload Capability on Automatic Bypass | 200% @ 5 min., 110% continuously | ||||||||
OUTPUT VOLTAGE REGULATION | |||||||||
Static | +/- 1% | ||||||||
0-100% Step Load | +/- 3% | ||||||||
SYSTEM EFFICIENCY | |||||||||
100% Load | 90.0 | 89.0 | 91.0 | 91.0 | 91.8 | 92.0 | 92.4 | 92.7 | 92.8 |
50% Load | 89.5 | 88.7 | 90.5 | 90.5 | 92.2 | 92.5 | 92.9 | 93.1 | 93.3 |
Ambient Operating Temp. | 32°-104°F (0°- 40°C) | ||||||||
Color | RAL 9003 (white) | ||||||||
Classifications and Listing | UL 1778 / IP20 / NEMA-PE-1 / ISO9001 | ||||||||
RFI and Surge Protection | EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance ** | ||||||||
Standard Connectivity | RS-232; programmable alarm contacts; programmable relays, SNMP (optional) | ||||||||
Warranty | Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first *** |
Technical Specs (225-300kVA)
GE SG Series 225-300 kVA high efficiency UPS Systems | |||||||||
---|---|---|---|---|---|---|---|---|---|
TOPOLOGY | True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass | ||||||||
TECHNOLOGY | Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency | ||||||||
OPERATING MODES | True on-line double conversion, automatic bypass, frequency converter, RPA™ up to eight (8) units | ||||||||
OUTPUT POWER RATING kVA | 225 | 300 | |||||||
Output Power Factor | .8 | ||||||||
Output Power Rating (kW) | 180 | 240 | |||||||
Dimensions W x D x H (inches) | 65 x 32 x 71 | ||||||||
Weight w/o Batteries (lbs) | 2756 | 3087 | |||||||
Noise Level dB(A) | 67 | ||||||||
Input Voltage (VAC) | 480V, 3 Phase, 4 Wire w/ground (grounded WYE) | ||||||||
Input Voltage Range | -20% to +15% (without battery discharge) | ||||||||
Input Frequency | 60Hz +/-10% | ||||||||
Input Power Factor | .8 PF (.93 with input filter) | ||||||||
Output Voltage (sinusoidal) (VAC) | 480V, 3 Phase, 4 Wire w/ground | ||||||||
Output Frequency | 60Hz +/-10% | ||||||||
Output THD at Linear Load | <2% | ||||||||
Output THD at Non-linear Load | <3% (IEC 62040) | ||||||||
Crest Factor | >3:1 | ||||||||
Overload Capability on Inverter | 125% @ 10 min., 150% @ 1 min. | ||||||||
Overload Capability on Automatic Bypass | 200% @ 5 min., 110% continuously | ||||||||
OUTPUT VOLTAGE REGULATION | |||||||||
Static | +/- 1% | ||||||||
0-100% Step Load | +/- 3% | ||||||||
SYSTEM EFFICIENCY | |||||||||
100% Load | 92.4 | 92.7 | |||||||
50% Load | 92.7 | 93.1 | |||||||
Ambient Operating Temp. | 32°-104°F (0°- 40°C) | ||||||||
Color | RAL 9003 (white) | ||||||||
Classifications and Listing | UL 1778 / IP20 / NEMA-PE-1 / ISO9001 | ||||||||
RFI and Surge Protection | EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance * | ||||||||
Standard Connectivity | RS-232; programmable alarm contacts; programmable relays, SNMP (optional) | ||||||||
Warranty | Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first ** |
Technical Specs (400-500kVA)
GE SG Series 400-500 kVA high efficiency UPS Systems | |||||||||
---|---|---|---|---|---|---|---|---|---|
TOPOLOGY | True on-line, double conversion (VFI) with integral static switch and internal maintenance bypass | ||||||||
TECHNOLOGY | Advanced IGBT with SVM strategy, microprocessor controlled at optimal switching frequency | ||||||||
OPERATING MODES | True on-line double conversion, automatic bypass, frequency converter, RPA™ up to eight (8) units | ||||||||
OUTPUT POWER RATING kVA | 400 | 500 | |||||||
Output Power Factor | .8 | .9 | |||||||
Output Power Rating (kW) | 320 | 450 | |||||||
Dimensions W x D x H (inches) | 81 x 33 x 77 | 81 x 33 x 77 | |||||||
Weight w/o Batteries (lbs) | 4600 | 5100 | |||||||
Noise Level dB(A) | 65 | ||||||||
Input Voltage (VAC) | 480V, 3 Phase, 4 Wire w/ground (grounded WYE) | ||||||||
Input Voltage Range | -20% to +15% (without battery discharge) | ||||||||
Input Frequency | 60Hz +/-10% | ||||||||
Input Power Factor | .8 PF (.93 with input filter) | ||||||||
Output Voltage (sinusoidal) (VAC) | 480V, 3 Phase, 4 Wire w/ground | ||||||||
Output Frequency | 60Hz +/-10% | ||||||||
Output THD at Linear Load | <2% | ||||||||
Output THD at Non-linear Load | <3% (IEC 62040) | ||||||||
Crest Factor | 3:1 | ||||||||
Overload Capability on Inverter | 125% @ 10 min., 150% @ 1 min. | ||||||||
Overload Capability on Automatic Bypass | 200% @ 5 min., 110% continuously | ||||||||
OUTPUT VOLTAGE REGULATION | |||||||||
Static | +/- 1% | ||||||||
0-100% Step Load | +/- 3% | ||||||||
FAULT CLEARING CAPABILITY | |||||||||
Inverter | – | 220% for 100 msec. / 700% for 1.2 msec | |||||||
Static Bypass | – | 100 KAIC | |||||||
SYSTEM EFFICIENCY | |||||||||
100% Load | 94.0 | 93.8 | |||||||
50% Load | 94.2 | 94.4 | |||||||
Ambient Operating Temp. | 32°-104°F (0°- 40°C) | ||||||||
Color | RAL 9003 (white) | ||||||||
Classifications and Listing | UL 1778 / IP20 / NEMA-PE-1 / ISO9001 | ||||||||
RFI and Surge Protection | EN 50091-2 / IEC 62040-2 / IEEE 587 B / FCC Class A compliance | ||||||||
Standard Connectivity | RS-232; programmable alarm contacts; programmable relays, SNMP (optional) | ||||||||
Warranty | Twelve (12) months after commissioning or eighteen (18) months after shipment, whichever occurs first * |
Technical Specs(750kVA)
GE SG Series 750 kVA high efficiency UPS System | ||||
---|---|---|---|---|
RECTIFIER CONFIGURATION | 6-PULSE (5TH FILTER) | 6-PULSE (5TH & 11TH FILTER) | 12-PULSE (W/O FILTER) | 12-PULSE (11TH FILTER) |
POWER RATING | ||||
Output Capacity | 750kVA / 675kW | |||
POWER FACTOR | ||||
Output Power Factor | 0.9 | |||
ENERGY EFFICIENCY | ||||
-50% Load | 94.2% | 94.1% | 92.1% | 92.0% |
-100% Load | 93.5% | 93.4% | 91.8% | 91.7% |
Heat Rejection (btu/hr) | 161,435 | 162,897 | 207,100 | 208,634 |
PHYSICAL | ||||
Weight w/o batteries (lbs / kg) | 9,557 / 4,335 | 9,696 / 4,398 | 11,091 / 5,031 | 11,230 / 5,094 |
Dimensions ( WxDxH) inches (mm) | 146.5 x 35.4 x 76.7 (3,720 x 900 x 1,950) inverter & rectifier cabinets | |||
INPUT | ||||
Input Voltage | 480 V, 3-phase, 4-wire w/ground (3-wire available) | |||
Voltage Range | -15% to +10% (w/o battery discharge) | |||
Frequency | 60 Hz +/- 5% | |||
Input THD | <7% | <5% | <9% | <4% |
Input Power Factor | 0.93 lagging | 0.96 lagging | 0.82 lagging | 0.86 lagging |
OUTPUT | ||||
Output Voltage | 480 V, 3-phase, 4-wire w/ground | |||
Frequency | 60 Hz +/- 0.01% free running — 60 Hz +/- 4% synchronized with utility | |||
Crest Factor | 3:1 | |||
Voltage Regulation | ||||
Static | +/- 1% | |||
100% Step Load | +/- 3% | |||
Voltage Distortion | ||||
100% Linear Load | 2% THD maximum | |||
100% Non-Linear Load | 3% THD maximum | |||
Overload Capability | ||||
Inverter | 125% for 10 minutes; 150% for 30 seconds | |||
Bypass | 110% continuous; 200% for 5 minutes | |||
BATTERY | ||||
Compatibility | VRLA or Wet cell | |||
Float Voltage | 545 VDC @ 68° F (20° C) | |||
Recharge Time | 10x discharge time (for battery runtime = 30 minutes) | |||
GENERAL | ||||
Audible Noise | 75 db(A) at 5 feet | |||
Operating Temperature | UPS: 32° to 104° F (0° – 40° C); Battery: 68° to 77° F (20° – 25° C) | |||
Humidity | 0-95%; non-condensing | |||
Safety Classifications & Listings | UL 1778 / IEC62040 / ISO 9001 | |||
Enclosure | IP20 and NEMA-PE-1 | |||
Communication / Connectivity | RS-232; programmable alarm contacts; programmable relays; SNMP (optional) | |||
Color | White (RAL 9003) | |||
Warranty | 12 months from start-up |
Industries & Applications
Designed for electrical engineering infrastructure in corporate, healthcare, banking, and industrial applications, the SG Series is particularly suited to:
- Smaller data centers
- Smaller telecom
- Hospitals, clinics, and medical centers
- Financial Institutions
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Highly reliable and efficient tri-level conversion
- Automatic or manual multi-mode operation
- Less than 5% Input Current Harmonic Distortion
- Unity (1.0) Output Power Factor
- High (0.99) Input Power Factor
- Less than 5% Input Current Harmonic Distortion
- Compact design
- Full front-maintainability
Industries & Applications
Designed for midsize datacenters, medical equipment facilities, and other mission-critical applications requiring a high quality power backup system, typical applications for the TLE Series include but are not limited to:
-
- Medium-to-larger data centers
- Hospital applications such as MRI, CT, or PET scanning equipment
- Financial Institutions
- Industrial applications
- Pharmacological manufacturing
We respect your privacy and will never share your email address with anyone without your explicit permission.

Features & Benefits
- Industry-leading energy efficiency reduces power and cooling costs
- Compact footprint combined with internal design redundancy conserve valuable datacenter floor space
- Vertical scalability can accommodate future increased power needs
- Innovative thermal management options, flexible configurability, and front access for all maintenance maximizes your deployment flexibility
- Can fit perfectly inline or alongside any standard-depth rack for simple installation
- Large user-friendly LCD touchscreen provides easy access to detailed status information
- Full suite of power management and connectivity software optimizes server virtualization solutions
- 24×7 remote monitoring and reporting capabilities ensure more uptime
Product Snapshot | |
---|---|
Power Rating | 20-400kW |
Voltage | 480V (208 with IAC-D) |
Frequency | 50/60 Hz |
Topology | Double conversion with optional Energy Saver System (ESS) |
Efficiency | Up to 97% in double conversion 99% in Energy Saver System |
Scalability | Up to 8 internal power modules External parallel up to 8 UPSs |
Configuration | Tower |
Batteries | Internal batteries up to 50 kW; external batteries up to 400 kW |
Technical Specs
POWER MODULES | |
---|---|
Power Offering (kW) | 50, 50+1, 100, 100+1, 150, 150+1, 200** (Derates available in 10 kW increments) |
GENERAL CHARACTERISTICS | |
Efficiency in Energy Saver System (ESS) | 99% |
Efficiency in double-conversion mode | Up to 97% |
Parallel Capability | 8 distributed |
INPUT CHARACTERISTICS | |
Voltage | 480V (208V with IAC-D) |
Voltage range | +10% / -15% |
Frequency range | 50/60 Hz |
Power factor | >.99 |
Input current distortion | <3% @ 100% load capacity |
OUTPUT | |
Voltage | 480V (208V with IAC-D) |
Regulation | ±1% steady state |
Voltage THD | <1% (100% linear load); <5% (non-linear load) |
Load power factor range | .8 leading to .8 lagging without de-rating |
BATTERY | |
Battery voltage | 432V |
Charging method | ABM® or float technology |
CERTIFICATION | |
Safety | UL1778, cUL |
EMC | FCC Part 15 subpart B class A |
Surge | IEC 61000-4-5 |
OPTIONAL ACCESORIES | |
External slim maintenance bypass Integrated distribution cabinet (with input and output transformer options) Integrated parallel tie cabinets Integrated battery cabinet (small and large) |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
The EATON 93PM is an ideal three-phase solution for providing a high quality power backup system for your white or gray datacenter space. Typical applications include but are not limited to:
- Medium-to-larger data centers
- Medical applications such as MRI, CT, or PET scanning equipment
- Financial Institutions
- Industrial applications
- Pharmacological manufacturing
We respect your privacy and will never share your email address with anyone without your explicit permission.
Recent Posts
- Master HP UL (65-500kVA 3-phase) 06/17/2021
- Sentryum (10-30kVA 3-phase) 06/17/2021
- Sentinel RT (1-10kVA) 06/10/2021
- N1C Lithium Ion UPS Systems earn 2019 Sustainable Product Award 12/18/2019
- Robot Ready to Roll at Evansville Middle School 11/29/2018
Address
2949 Venture Drive, Dock 190
Janesville, WI, 53546
Hours: M-F, 8am-5pm CDT