Features & Benefits
- High efficiency at all loads
- Can operate between 0°C to 40°C
- Advanced battery protection
- Hot-swappable batteries
- Regular automatic battery test
- Short circuit and overload protection
- Cold start
- 50/60 auto-sensing—can be used as a frequency converter
- Energy-saving eco-friendly 95 percent efficiency
- At-a-glance LED display of system status
Product Specifications
Single Phase Output Voltages | 125V |
50/60 auto-sensing | Can be used as a frequency converter |
95% efficiency | Low losses and greater energy savings |
Intelligent LED display | Quick visual of UPS, load and battery status |
Wide operating temperature | UPS can operate between 0°C to 40°C |
Technical Specs
GE IT Series UPS Technical Specifications | |||
---|---|---|---|
MODEL NUMBER | UPS0600ITSIT , UPS1000ITSIT , UPS1500ITSIT , UPS2000ITSIT | ||
POWER RATING | OUTPUT CAPACITY | 600VA / 360W , 1000VA / 600W , 1500VA / 900W , 2000VA / 1200W | |
POWER FACTOR | OUTPUT POWER FACTOR | 0.6 pf | |
INPUT | VOLTAGE FREQUENCY INPUT POWER CONNECTION |
120V +/- 10% at line input, single phase 50 or 60 Hz +/- 5Hz auto-sensing Detachable 5-15P , Detachable 5-15P , Hardwired 5-15P , Hardwired 5-20P |
|
OUTPUT | VOLTAGE (on battery) VOLTAGE (on mains) VOLTAGE THD FREQUENCY (on battery) VOLTAGE REGULATION (AVR)OUTPUT RECEPTACLES – POWER DISTRIBUTION |
Pure sine wave at +/- 5% of nominal, -10% of nominal after low battery warning 120V, -12%/+10% < 5% @ 100% resistive load with 80% battery capacity 50 or 60 Hz +/- 5% auto-sensing AVR automatically increases (boost) output voltage 17% above input voltage if -9% to -25% of nominal. AVR decreases (buck) output voltage 14% below input voltage if +9% to +25% of nominal.(4) 5-15R , (4) 5-15R , (6) 5-15R , (6) 5-15R |
|
PROTECTION & FILTERING | SPIKE PROTECTION EMI/RF FILTER OVERLOAD PROTECTION TRANSFER TIME SHORT CIRCUIT |
780 Joules/6500A 10dB @ 0.15MHz, 50 dB @ 30 MHz UPS automatic shutdown if overload exceeds 110% of nominal @ 20 seconds and 125% @ 5 seconds 4/6 milliseconds (typical), including detection time Active protection with automatic shutdown |
|
BATTERY | SYSTEM TYPE BATTERY TYPICAL RECHARGE TIME PROTECTION BATTERY QUANTITY |
Hot swappable, sealed Valve Regulated Lead Acid (VRLA) 12V / 9.0 AH 4 hours (to 90% of full capacity) Automatic self-test and discharge protection, Replace battery indicator 2 pcs , 2 pcs , 3 pcs , 4 pcs |
|
NET WEIGHT(lbs) DIMENSIONS WxDxH(inches) |
30.4 lbs , 33.0 lbs , 55.0 lbs , 66.0 lbs 5.5″ x 17.2″ x 8.3″ , 5.5″ x 17.2″ x 8.3″ , 6.7″ x 17.7″ x 8.9″ , 6.7″ x 17.7″ x 8.9″ |
||
COMMUNICATIONS | RS-232 USB SNMP OPERATING SYSTEM |
Standard (Detect battery low, schedule UPS on/off, AC Input/Output power status display) Standard Optional Windows NT, Windows 2000/ME, Windows XP, Linux |
|
ENVIRONMENT | AMBIENT OPERATION AUDIBLE NOISE @ 1 METER STORAGE CONDITION |
3,500 meters max. elevation, 0-95% RH non-condensing, 0-40°C < 40 dBA , < 45 dBA 15,000 meters max. elevation, 0-95% RH non-condensing, 0-40°C |
|
CERTIFICATIONS | UL, cUL, FCC Class A |
1. Due to continuous product improvements, program specifications are subject to change without notice.
Industries & Applications
The IT Series by GE is an ideal battery backup power supply for one- or two-rack users in clinics & hospitals, financial institutions, businesses, and other sites in need of a commercial UPS system that offers superior online power quality and scalable battery runtimes in applications including but not limited to:
- Smaller data centers, IT systems, or telecom closets
- Network switching & processing equipment
- PLC controls
- High-quality power backup system for AS-400 systems