Easy to install and maintain, and versatile enough to accommodate office environments as well as more-demanding commercial and industrial ones, the LP 11 Series by GE is a true-voltage, frequency-independent, double conversion, online UPS system designed to provide the highest level of protection for all critical loads against all utility variances and failure.

Highly scalable, the GE proprietary redundant parallel architecture allows you to parallel up to four units as increasing business growth might require, as well as simultaneously enhancing total system reliability, and eliminating the possibility of single points of failure.

Ergonomically designed LCD interface provides clear status data, functions as a service screen to adjust UPS parameters, and includes a comprehensive event log. Integrated transformer ensures galvanic isolation on the output for ultimate safe installation. Available with optional matching battery cabinets to extend runtime, the LP 11 Series comes with a comprehensive warranty.


 

Features & Benefits

  • High efficiency at all loads
  • Can operate between 0°C to 40°C
  • Advanced battery protection
  • Hot-swappable batteries
  • Regular automatic battery test
  • Short circuit and overload protection
  • Cold start
  • 50/60 auto-sensing—can be used as a frequency converter
  • Energy-saving eco-friendly 95 percent efficiency
  • At-a-glance LED display of system status

Request a quote

 

Product Scope

Single Phase Output Voltages 120/208/230/240V
Wide input voltage window Minimizes battery use, prolongs battery life
RPA functionality for paralleling and redundancy UPS capacity can be increased as site requirements require at no extra cost
Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
0.8 output power factor Prevents the need to oversize the UPS
0.99 input power factor
Manual automatic bypass switch Integrated as standard to the rear of the UPS
GE’s unique Superior Battery Management Ultimate protection for the UPS core component
High efficiency 91% – 94% (model dependent) Using ECO mode, high efficiency and low losses
No load shutdown Prevents deep battery discharge al low loads
Frequency conversion 50/60Hz Operates as a frequency converter also operating in a parallel system

 

Technical Specs

GE LP-11U Series UPS (5kVA-10kVA) Technical Specifications
MODEL NUMBER LP11U-5 LP11U-5 (120) LP11U-6 LP11U-6 (120V) LP11U-8 LP11U-10
Rating (VA/W) 5000 / 4000 5000 / 4000 6000 / 4800 6000 / 4800 8000 / 6400 10,000 / 8000
Backup Time @ 50% / 100% loads 25 / 10 min. 25 / 10 min. 20 / 8 min. 20 / 8 min. 29 / 11 min. 22 / 8 min.
Enclosure (Table 1) A B A B A A
Net Wgt Incl. Batteries (kg/lbs) 134/295 175/386 134/295 175/386 175/386 186/410
Input Voltage (VAC)
Nominal 208 120 208 120 208 208
Range @ 100% Load (V) 162-285 81-141 162-285 81-141 162-285 162-285
Range @ 50% Load (V) 146-285 72-141 146-285 72-141 146-285 146-285
Input Power Factor .99
Input Frequency (Hz) 40-70
Output Power Factor .8
Output Voltage (VAC) (sinusoidal) 120+208+220/230/240 User Selectable
Output Frequency (Hz) 50/60
Output Voltage Regulation +/- 1%
Output THD at Linear Load <1%
Output THD at Non-linear Load <2%
Crest Factor Handling Capacity of a Non-linear Load 5:1
Overload Capability on Inverter 110% 20 min., 130% 3.5 min., 150% 2 min.
Color Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)
Environment IP20 (IEC 60529)
Operating Temperature / Humidity 32° F – 104° F (0° C – 40° C) / 95% Non-condensing
Audible Noise 40-50 dBA – 3.3 feet (1 meter)
Safety Classifications & Listings UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950
EMI FCC Part 15 Class A / EN50091-2
Surge Protection IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2
Connectivity RS-232; programmable alarm contacts (optional); SNMP (optional)
Warranty 24 Months

1. Due to continuous product improvements, program specifications are subject to change without notice.

 

Industries & Applications

  • Hospitals, clinics, medical centers
  • Government & business offices
  • Police & fire emergency call centers
  • Military applications
  • “Lights-out” or “dark factory” manufacturing
  • Large data centers or IT systems
  • Critical network switching & processing equipment
  • Large-scale PLC controls

Request a quote

We respect your privacy and will never share your email address with anyone without your explicit permission.

Ideal for servers supporting varying load levels, the IT Series by GE is a robust commercial UPS system or industrial UPS system for providing cost-effective protection against power outages, voltage fluctuations, and transient surges for sensitive equipment. Line-interactive with automatic voltage regulation (AVR) to ensure sine wave purity, it’s available in both tower and 19-inch rack formats. Standard features include hot-swappable batteries, RS232 and USB communication ports, and a RJ11 port for telephone/modem protection. Product warranty is a full two years.

Features & Benefits

  • High efficiency at all loads
  • Can operate between 0°C to 40°C
  • Advanced battery protection
  • Hot-swappable batteries
  • Regular automatic battery test
  • Short circuit and overload protection
  • Cold start
  • 50/60 auto-sensing—can be used as a frequency converter
  • Energy-saving eco-friendly 95 percent efficiency
  • At-a-glance LED display of system status

Request a quote

Product Specifications

Single Phase Output Voltages 125V
50/60 auto-sensing Can be used as a frequency converter
95% efficiency Low losses and greater energy savings
Intelligent LED display Quick visual of UPS, load and battery status
Wide operating temperature UPS can operate between 0°C to 40°C

 

Technical Specs

GE IT Series UPS Technical Specifications
MODEL NUMBER UPS0600ITSIT , UPS1000ITSIT , UPS1500ITSIT , UPS2000ITSIT
POWER RATING OUTPUT CAPACITY 600VA / 360W , 1000VA / 600W , 1500VA / 900W , 2000VA / 1200W
POWER FACTOR OUTPUT POWER FACTOR 0.6 pf
INPUT VOLTAGE
FREQUENCY
INPUT POWER CONNECTION
120V +/- 10% at line input, single phase
50 or 60 Hz +/- 5Hz auto-sensing
Detachable 5-15P , Detachable 5-15P , Hardwired 5-15P , Hardwired 5-20P
OUTPUT VOLTAGE (on battery)
VOLTAGE (on mains)
VOLTAGE THD
FREQUENCY (on battery)
VOLTAGE REGULATION (AVR)OUTPUT RECEPTACLES – POWER DISTRIBUTION
Pure sine wave at +/- 5% of nominal, -10% of nominal after low battery warning
120V, -12%/+10%
< 5% @ 100% resistive load with 80% battery capacity
50 or 60 Hz +/- 5% auto-sensing
AVR automatically increases (boost) output voltage 17% above input voltage if -9% to -25% of nominal.
AVR decreases (buck) output voltage 14% below input voltage if +9% to +25% of nominal.(4) 5-15R , (4) 5-15R , (6) 5-15R , (6) 5-15R
PROTECTION & FILTERING SPIKE PROTECTION
EMI/RF FILTER
OVERLOAD PROTECTION
TRANSFER TIME
SHORT CIRCUIT
780 Joules/6500A
10dB @ 0.15MHz, 50 dB @ 30 MHz
UPS automatic shutdown if overload exceeds 110% of nominal @ 20 seconds and 125% @ 5 seconds
4/6 milliseconds (typical), including detection time
Active protection with automatic shutdown
BATTERY SYSTEM TYPE
BATTERY
TYPICAL RECHARGE TIME
PROTECTION
BATTERY QUANTITY
Hot swappable, sealed Valve Regulated Lead Acid (VRLA)
12V / 9.0 AH
4 hours (to 90% of full capacity)
Automatic self-test and discharge protection, Replace battery indicator
2 pcs , 2 pcs , 3 pcs , 4 pcs
NET WEIGHT(lbs)
DIMENSIONS WxDxH(inches)
30.4 lbs , 33.0 lbs , 55.0 lbs , 66.0 lbs
5.5″ x 17.2″ x 8.3″ , 5.5″ x 17.2″ x 8.3″ , 6.7″ x 17.7″ x 8.9″ , 6.7″ x 17.7″ x 8.9″
COMMUNICATIONS RS-232
USB
SNMP
OPERATING SYSTEM
Standard (Detect battery low, schedule UPS on/off, AC Input/Output power status display)
Standard
Optional
Windows NT, Windows 2000/ME, Windows XP, Linux
ENVIRONMENT AMBIENT OPERATION
AUDIBLE NOISE @ 1 METER
STORAGE CONDITION
3,500 meters max. elevation, 0-95% RH non-condensing, 0-40°C
< 40 dBA , < 45 dBA
15,000 meters max. elevation, 0-95% RH non-condensing, 0-40°C
CERTIFICATIONS UL, cUL, FCC Class A

1. Due to continuous product improvements, program specifications are subject to change without notice.

 

Industries & Applications

The IT Series by GE is an ideal battery backup power supply for one- or two-rack users in clinics & hospitals, financial institutions, businesses, and other sites in need of a commercial UPS system that offers superior online power quality and scalable battery runtimes in applications including but not limited to:

  • Smaller data centers, IT systems, or telecom closets
  • Network switching & processing equipment
  • PLC controls
  • High-quality power backup system for AS-400 systems

 

We respect your privacy and will never share your email address with anyone without your explicit permission.

The Digital Energy™ VH Series by GE is a true-voltage, frequency-independent, double conversion, online UPS system designed to provide robust protection against voltage fluctuations and power outages for datacenter, telecom, laboratory, and mission-critical applications. Available in either tower or rack design, the VH Series has a 0.9 power factor and comes with a standard three-year warranty.

Features & Benefits

  • High efficiency at all loads
  • Can operate between 0°C to 40°C
  • Advanced battery protection
  • Hot-swappable batteries
  • Regular automatic battery test
  • Short circuit and overload protection
  • Cold start
  • Energy-saving eco-friendly 95 percent efficiency
  • At-a-glance LED display of system status

Request a quote

 

Product Specifications

Unique failsafe internal bypass Continued operation even with overload or over-temperature
2U design for all ratings Small footprint; parts supplied for tower or rack assembly
Hot swappable batteries Simple, fast battery replacement without disruption to the load
Matching battery cabinets Longer battery life available with the addition of extra battery cabinet(s)
Superior battery management Provides protection to the battery and extends the battery life
Remote monitoring Easy access and control even for unmanned or isolated sites
MTBF >730,000 hours Proven reliability
Increased power handling 0.9 output power factor delivers more actual power to the load

 

Technical Specs

GE VH Series UPS Technical Specifications
VH SERIES 700 , 1000 , 1500 , 2000
Voltage Amperes (VA) with computer type load
Watts (W) with resistive load
700 , 1000 , 1500 , 1920
630 , 900 , 1350 , 1740
INPUT CONVERTER
AC input voltage
Input current waveform
Input current (A) at nominal input voltage
Input power factor
Input frequency range
Inrush current
60 – 140V
Sinusoidal, EN 61000-3-2(IEC 555-2) compliant
6.6 , 9.1 , 13.9 , 16
1
45-66
none
OUTPUT CONVERTER
AC output voltage
Output frequency
Output waveform
Power Factor
Capacity appliance outlets
100 / 110 / 115 / 120 / 127V (selectable)
Auto selectable or 50/60 Hz, front selectable
Sine wave
0.9
max. 20A per outlet (+1 high power outlet max. 20A, on 2000VA model only)
BYPASS
AC input voltage range
Frequency tracking rate
Frequency tracking range
Phase difference
Typical transfer time, msec
Selected output voltage -15% to +10%
“2 Hz / sec
nominal ±10% / ±2% selectable
<1° typical (max.7° during tracking frequency range)
1
BATTERIES (rating given for 77°F)
Nominal voltage (Vdc)
Number / Ah batteries
Type
Service life
Recharge current
Battery recharge time (batt. discharge at 100% load)
Runtime in minutes at typical load (75%)
36 , 36 , 72 , 72
3/7 , 3/9 , 6/7 , 6/9
Sealed lead acid , maintenance free
up to 6 years (depending on use)
1.5 A
3 hours for 90% capacity, std battery
12 , 12 , 11 , 12
GENERAL
Weight UPS (lbs/kg)
Dimensions UPS (HxWxD)Enclosure / protection
35/16 , 37/17 , 64/29 , 71/32
3.4×17.2×18.5 inch , 3.4×17.2×21.3 inch
87x438x470 mm , 87x438x540 mm
steel-plastic / IP20
ENVIROMENT
Safety
Electromagnetic compatibility
Ambient temperature
Audible noise at 1 meter
Max. relative humidity
UL 1778, 4th Edition
EN 62040-2
32 to 104°F (o to +40°C)
< 45 dB(A), load and temperature dependent
95% (non-condensing)

 

Industries & Applications

The VH Series UPS is a more powerful solution in a compact footprint for smaller users who have relatively denser power requirements in clinics & hospitals, financial institutions, businesses, and other sites in need of an emergency power supply system. Available in rack or tower platforms and perfect for applications including but not limited to:

  • Smaller data centers, IT systems, or telecom closets with relatively larger power needs
  • Network switching & processing equipment
  • PLC controls
  • High-quality power backup system for AS-400 systems

Request a quote

 

We respect your privacy and will never share your email address with anyone without your explicit permission.

Easy to install and maintain, the transformerless GT Series is a true voltage & frequency independent, online, double-conversion UPS designed to provide robust power protection for a wide range applications. Both its power and redundancy are expandable by adding units (N2) to create a parallel system. Available in tower or rack configurations. Standard features include standard remote monitoring, simplifying operation from remote or unmanned sites, as well as an RS-232 port and contact interface. Options include a Web-enabled SNMP card.

Features & Benefits

  • Fully-digitized microprocessor control for reliable performance
  • At-a-glance LED display of system status
  • Programmable outlet allows selective shutdown for lower priority loads
  • Quiet operation is ideal for office and medical environments
  • Advanced battery protection
  • Cold start capability
  • Hot swappable batteries
  • Multiple PDU options

Request a quote

 

Product Specifications

GT Series UPS – UL Listed (3kVA)
Single Phase Output Voltage 110V with 208V optional on 3kVA units
Wide input voltage window 80-138V Minimizes battery use, prolongs battery life
Pulse Width Modulation technology Eliminates the need to oversize the UPS
Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
Low input distortion Prevents disturbance to nearby electrical equipment
GT Series UPS – UL Listed (5-10kVA)
Single Phase Output Voltages 120/208V
Wide input voltage window 80-138V Minimizes battery use, prolongs battery life
Redundant and paralleling capability UPS capacity can be increased as site requirements require at no extra cost
Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
No load shutdown Prevents deep battery discharge al low loads
Frequency conversion 60/50Hz Automatic frequency detection

 

Technical Specs (3kVA)

GT Series UPS Technical Specification (3kVA)
MODEL NUMBER GT3000R , GT3000T208
RATING (VA/W) 3000 / 2400 , 3000 / 2400
BATTERY (V/Ah) 2000VA/1200W , 3000VA/1800W
BACKUP TIME @50% LOAD (25°C) 14 min.
OPTION FOR ADDITIONAL BATTERIES Yes
DIMENSIONS (HxWxD) 13.2×43.9×50.3cm (5.2×17.3×19.8in) , 37.3x14x42.4cm (14.7×5.5×16.7in)
NET WGT INCL. BATTERIES (kg / lbs) 34 / 74.9 , 30 / 66
INPUT VOLTAGE @ 100% LOAD (VAC) 80-138 , 160-275
INPUT FREQUENCY (Hz)* 50/60
OUTPUT VOLTAGE 100/110 , 160/208
NUMBER OF OUTLETS (4)NEMA 5-15R , (4)NEMA 6-20R
(1)NEMA L5-20R , (1)NEMA L6-20R
(1)NEMA L5-30R
SNMP COMPATIBILITY Yes
CORE VOLTAGE 120
PWM (PULSE WIDTH MODULATION) Yes
MAINTENANCE BYPASS Yes
INTERNAL BATTERIES Yes
INPUT PERFORMANCE RANGE Voltage (-33 to +17%); Frequency (55 to 65 Hz)
OUTPUT PERFORMANCE
OUTPUT THD LOAD Non-Linear (<6%); Linear (<3%)
VOLTAGE REGULATION LOAD Static (2%); 0-100% Step (8%)
OVERLOAD CAPABILITY 150% for 30 seconds
EFFICIENCY >87%
COMMUNICATIONS INTERFACE RS-232, Plug and Play, open collector alarm contacts
COLOR Front bezel: Aluminum Grey (RAL9006); Cabinet: White (RAL9010)
OPERATING TEMPERATURE 32° F – 104° F (0° C – 40° C)
RELATIVE HUMIDITY 95% non-condensing
AUDIBLE NOISE AT 3.3FT (1 METER) 47 dBA , 42 dBA
SAFETY UL 1778, CSA22.2-107, IEEE 62.41 CAT. A Lightning Safety
EMC FCC Class B (1kVA), FCC Class A (remaining), CISPR PUB. 22 Class A
ENCLOSURE NEMA1

GT Series UPS Technical Specification (5-10kVA)
MODEL NUMBER GT5000 RT GT6000 RT GT8000 RT GT10000 RT
RATINGS :
Power Rating Depending on Input Voltage VA/W VA/W VA/W VA/W
100V / 200V 4000 / 3400 4800 / 3400 6400 / 6400 8000 / 6400
110V / 220V 4500 / 3800 5400 / 3800 7200 / 7200 9000 / 7200
115V / 230V 5000 / 4000 60000 / 4200 8000 / 6900 8700 / 8000
120V / 208V 4800 / 4200 5200 / 4200 8000 / 6900 8700 / 8000
120V / 240V 5000 / 4200 6000 / 4200 8000 / 8000 10000 / 8000
127V / 220V 4800 / 4200 5200 / 4200 8000 / 6900 8700 / 8000
Input Thermal Circuit Breaker (A) 30 60
Internal Input Fuse 250V, Slow (A) Qty 30 30/2
INPUT CONVERTER :
AC Input Voltage Nominal:120/208V
AC Input Voltage Range 100/(173-200), 110/(190-220), 115/(198-230), 120/(208-240), 127/(220) V
Input Current Waveform Sine Wave
Input Current (A) at Nominal Input Voltage 20 40
Input Power Factor >0.97
Input Frequency Range 40 – 70 Hz
Input phase (L1 to L2) 120° / 180° / 240° ±10°
Inrush Current 40
OUTPUT CONVERTER :
AC Output Voltage 100 / 110 / 115 / 120 / 127 V (selectable)
AC Output Voltage Tolerance L-N ± 3%; L1-L2 ± 5% L-N ± 2%; L1-L2 ± 5%
Output Frequency 50 / 60 Hz, auto selection
Output Frequency Range nominal ± 5% with mains synchronizing
Output Waveform Sine wave
Harmonic Distortion < 3% with linear load, < 5% with non-linear full load
Power Factor at Nominal Input Voltage 0.87 0.8 0.86 0.92
Crest Factor (Peak to RMS Current) ≤ 3 : 1
Capacity Appliance Outlets with 55A Terminal Block
BYPASS :
AC Input Voltage Range ± 15% of selected output voltage
Frequency Tracking Rate 1Hz/s
Frequency Tracking Range ± 5% of selected frequency
Typical Transfer Time, msec 0
OVERLOAD CAPABILITY :
Overload Behavior During Battery Operation 130% for 10 seconds
200% for 2 seconds
130% for 1 minute
200% for 5 seconds
Overload Behavior During Bypass Operation Depends on rating of thermal circuit breaker (TCB)
125% of TCB value for 200 seconds
200% of TCB value for 10 seconds
300% of TCB value for 4 seconds
Overload protection
110% of TCB value for 300 seconds
130% of TCB value for 30 seconds
200% of TCB value for 5 seconds
BATTERIES (RATINGS GIVEN FOR 25º C) :
Nominal Voltage(Vdc) 144 288
Qty / Ah (In Battery Kit & Battery Ext. Pack) 12 pcs / 8Ah 24 / 8Ah
Type REW45-12 FR
Recharge Current 1A
Battery Recharge Time (Batt. Discharged at 100% Load) 6 hours for 90% capacity 3 hours for 90% capacity
GENERAL :
Weight UPS 30.3 Kg (67 lbs) 49.3 Kg (109 lbs)
Dimensions UPS (HxWxD) 176x430x592 mm (6.9×16.9×22.55 in) 267x430x660 mm (10.5×16.9×26 in)
Weight Battery Pack 43 Kg (94.7 lbs) 91 Kg (200.4 lbs)
Dimensions Battery Pack 87x430x592 mm (3.47×16.9×2255 in) 173x430x660 mm (6.8×16.9×26 in)
Enclosure / Protection steel-plastic / IP20
Mounting Rackmount or Tower mount with same unit
ENVIROMENT :
Safety Compliance UL 1778
Electromagnetic Compatibility EMI: FCC CFR47 Part 15, class A, ESD:
IEC61000-4-2, level 4
RS: IEC61000-4-3, level 3, EFT: IEC61000-4-4,
level 4, Surge: IEC61000-4-5, level 3
ANSI C62.41 (IEEE587) Category A
(level 3) & B (level 1)
Ambient Temperature 0 to +40ºC
Audible Noise at 3.3 ft. <55 dB(A), load and temperature dependent
Max. Relative Humidity 90% (non-condensing)
Color Black – RAL 9005

1. Due to continuous product improvements, program specifications are subject to change without notice.

 

Industries & Applications

The VH Series UPS is a more powerful solution in a compact footprint for smaller users who have relatively denser power requirements in clinics & hospitals, financial institutions, businesses, and other sites in need of an emergency power supply system. Available in rack or tower platforms and perfect for applications including but not limited to:

  • Smaller data centers, IT systems, or telecom closets with relatively larger power needs
  • Network switching & processing equipment
  • PLC controls
  • High-quality power backup system for AS-400 systems

 

We respect your privacy and will never share your email address with anyone without your explicit permission.

Quiet, compact, and easy to maintain, the office-friendly Digital Energy™ LP11U Series by GE is a high-performance UPS system especially designed to provide protection for a wide range of mission-critical applications in power-dense applications. Full-time double conversion mode—along with true online voltage & frequency independent operation—ensure maximum protection for your industrial UPS system or commercial UPS system. For increased power capacity and/or to ensure redundancy, the proprietary Redundant Parallel Architecture™ enables the LP11U Series to be paralleled to as many as to four units.

Features & Benefits

  • Compact footprint and low noise
  • Easy to maneuver and install
  • Suitable for installation even next to the user
  • Isolation transformer design for ultimate site safety
  • PDU options to suit various output configurations

Request a quote

 

Product Snapshot

Single Phase Output Voltages 120/208/230/240V
Wide input voltage window Minimizes battery use, prolongs battery life
RPA functionality for paralleling and redundancy UPS capacity can be increased as site requirements require at no extra cost
Internal automatic bypass switch Continuous power supply to the load even if the UPS is overloaded
0.8 output power factor Prevents the need to oversize the UPS
0.99 input power factor
Manual automatic bypass switch Integrated as standard to the rear of the UPS
GE’s unique Superior Battery Management Ultimate protection for the UPS core component
High efficiency 91% – 94% (model dependent) Using ECO mode, high efficiency and low losses
No load shutdown Prevents deep battery discharge al low loads
Frequency conversion 50/60Hz Operates as a frequency converter also operating in a parallel system

 

Technical Specs

GE LP-11U Series UPS (5kVA-10kVA) Technical Specifications
MODEL NUMBER LP11U-5 LP11U-5 (120) LP11U-6 LP11U-6 (120V) LP11U-8 LP11U-10
Rating (VA/W) 5000 / 4000 5000 / 4000 6000 / 4800 6000 / 4800 8000 / 6400 10,000 / 8000
Backup Time @ 50% / 100% loads 25 / 10 min. 25 / 10 min. 20 / 8 min. 20 / 8 min. 29 / 11 min. 22 / 8 min.
Enclosure (Table 1) A B A B A A
Net Wgt Incl. Batteries (kg/lbs) 134/295 175/386 134/295 175/386 175/386 186/410
Input Voltage (VAC)
Nominal 208 120 208 120 208 208
Range @ 100% Load (V) 162-285 81-141 162-285 81-141 162-285 162-285
Range @ 50% Load (V) 146-285 72-141 146-285 72-141 146-285 146-285
Input Power Factor .99
Input Frequency (Hz) 40-70
Output Power Factor .8
Output Voltage (VAC) (sinusoidal) 120+208+220/230/240 User Selectable
Output Frequency (Hz) 50/60
Output Voltage Regulation +/- 1%
Output THD at Linear Load <1%
Output THD at Non-linear Load <2%
Crest Factor Handling Capacity of a Non-linear Load 5:1
Overload Capability on Inverter 110% 20 min., 130% 3.5 min., 150% 2 min.
Color Front bezel: Aluminum Grey (RAL9006); Cabinet: Pure White (RAL9010)
Environment IP20 (IEC 60529)
Operating Temperature / Humidity 32° F – 104° F (0° C – 40° C) / 95% Non-condensing
Audible Noise 40-50 dBA – 3.3 feet (1 meter)
Safety Classifications & Listings UL, cUL 1778; CE: EN50091-1-1; EN 60950; IEC 950
EMI FCC Part 15 Class A / EN50091-2
Surge Protection IEC 1000-4-5 (6kV 1.2/50 μsec – 3kA 8/20 μsec) IEEE 587 B, EN 50091-2
Connectivity RS-232; programmable alarm contacts (optional); SNMP (optional)
Warranty 24 Months
1. Due to continuous product improvements, program specifications are subject to change without notice.

 

Industries & Applications

  • Hospitals, clinics, medical centers
  • Government & business offices
  • Police & fire emergency call centers
  • Military applications
  • “Lights-out” or “dark factory” manufacturing
  • Large data centers or IT systems
  • Critical network switching & processing equipment
  • Large-scale PLC controls