Description

*Image shows UPS only. Transformer included. Lithium Battery (EBM) sold separately.
Main Features:
- 6 kVA UPS + 6kW Step-Down Transformer Bundle
- Uses 100Ah or 50Ah external lithium iron phosphate batteries for long runtimes
- 208-240VAC Input, 208/240/120V Output via included 6kW Transformer
- 3U Height UPS + 2U Height Transformer + 2U or 3U Height for each External Battery Module (EBM)
- 19″ Rack Mountable
- Hardwire on UPS + (4) NEMA 5-20R 120V outlets + (1) L6-30R 240V outlet + (1) L14-30R 240/120V outlet
- Standard with SNMP Communication Port and 1000 Node Software Suite
- Conformal Coating
- Connect up to 10 External Battery Modules for extended runtime
- ~25 Minutes of back up time at 100% load (6000VA/5400W) with 1 external 50Ah battery module
- ~50 Minutes of back up time at 100% load (6000VA/5400W) with 1 external 100Ah battery module
- Rack Rails Included
- The Industry’s ONLY 10-year Warranty
Application
19″ Rack Device, Computer Room, Data Center, Point-of-Sale, Router, Hub, and Network Device, Commercial Facility, Precision Instrument.

Specifications
N1C.LR6000S
INPUT
- Voltage (Vac): 208-240V
- Frequency (Hz): 50/60±5%
- Power Factor: 0.9
OUTPUT
- Capacity (VA/W): 6000/5400
- Up to 36kVA when connecting multiple UPS modules
- Voltage (Vac): 240/120V±2% with Step-Down Transformer
- Frequency (Hz): 50/60±0.1% (battery mode)
- Waveform: Sine wave, THD<3% at linear load
- Transfer time: 0ms
- Overload: 105~125% for 10 minutes, 125-150% for 30 seconds
- Input connection: Hardwire
- Output: Hardwire on UPS + (4) 5-20R + (1) L6-30R + (1) L14-30R on Transformer
BATTERY
- Voltage (Vdc): 48
- 50Ah or 100Ah battery
- Lithium Iron Phosphate
- Cycle Life: 8,000 cycles at 77ºF
- Parallel Connectable: Yes
- LED Display: Battery Status, Battery, Level, Battery Fault, Alarms
Run Time at 100%/50% Load (hours:minutes) per 50Ah EBM:
1EBM – 00:25/00:50
Charger Current (A): 10A, battery monitoring system included
OTHER:
- Communications Interface: USB, EPO and SNMP/Network Card all standard, Dry Contact optional
- Topology: Online Double Conversion
- Alarm: Low battery, abnormal AC input, UPS failure
- Protection: Low Battery, overload, short-circuit, over temperature
- Working Temperature: 32º-122
- Relative Humidity: 0~95%, no condensation
- UPS Dimensions (HxWxD): 5.2” (3U) x 17.2” x 16.3”
- Transformer Dimensions (HxWxD): 3.4” (2U) x 17.2” x 20.6”
- Battery Dimensions: 3.5” (2U) x 17.2” x 24.8” (50Ah) or 5.2” (3U) x 17.2” x 24.8” (100Ah)
- Net Weight: 73lbs UPS + 104lbs Transformer + selected total battery weight