04
Apr
N1 Critical Technologies (lithium-ion-ups.com) has announced the launch of all new three-phase, Lithium-Ion-based uninterruptible power supply (UPS) systems, becoming one
Total front-access design requires zero rear-clearance and includes convenient features such as top, bottom, and/or side cable entry, standard sized air filter provisions, and lockable keyed doors. Small footprint and intuitive local touchscreen interface make it versatile and user-friendly, and it can be customized to your specific needs with such options as internal battery backup, internal transformers for specific voltage applications, and remote monitoring with the Toshiba RemotEye® 4 multi-protocol UPS.
MODEL | Model Number | 4400X3X150XA | 4400X3X200XA | 4400X3X250XA | 4400X3X300XA | 4400X3X500XA | 4400X3X800XA |
Capacity | 15 kVA (13.5 kW) | 20 kVA (18 kW) | 25 kVA (22.5 kW) | 30 kVA (27 kW) | 50 kVA (45 kW) | 80 kVA (72 kW) | |
Topology | True On-Line, Double-Conversion, All-IGBT Technology | ||||||
INPUT | Voltage (Standard) | 208/120V Three-phase, Four-Wire + Ground Input* | |||||
Voltage Range | -15% to +10% (Without Using Battery) | ||||||
Power Factor | > 0.98 | ||||||
Current THD | < 5% at 100% Load | ||||||
Frequency | 50 ±5 Hz; 60 ±5 Hz | ||||||
OUTPUT | Voltage (Standard) | 208/120 V: Three-Phase, Four-Wire + Ground** | |||||
Frequency | 50/60 Hz, ±0.1% Auto-Sensing Standard. (50/60Hz Selectable, for use as Frequency Converter) |
||||||
Voltage Regulation | ±2.0% | ||||||
Power Factor | 0.9 Lagging | ||||||
Overload | Inverter: 125% for 90 Seconds, 150% for 30 Seconds Bypass: 125% for 10 Minutes, 1000% for 10 Milliseconds |
||||||
BATTERY | DC Link | 288 VDC | |||||
Ripple Voltage | < 0.5% DC | ||||||
ENVIRONMENT | Temperature Range | 32° to 104°F (0° to 40°C) | |||||
Relative Humidity | 5% to 95% Non-Condensing | ||||||
Heat Rejection | 4556 BTUs/Hour |
6074 BTUs/Hour |
7395 BTUs/Hour |
9111 BTUs/Hour |
15,186 BTUs/Hour |
24,297 BTUs/Hour |
|
Full-Load Efficiency | 91.0% | ||||||
25% Load Efficiency | 88.8% | ||||||
Altitude | 3300 ft. (1000 m) Maximum Without Derating | ||||||
Air Filtration | Airflow Front to Top with Provisions for Front-Located Air Filters |
||||||
DIMENSIONS | Dimensions | 20.12″ (W) x 37.4″ (D) x 65.06″ (H) (511mm x 950mm x 1653mm) |
32.1″ (W) x 31.8″ (D) x 73.6″ (H) (816mm x 807mm x 1870mm) |
||||
Weight*** | 720 lbs. (326 kg) | 1350 lbs. (612 kg) | 1500 lbs. (680 kg) | ||||
COLOR | O’Brien Black (Textured Powder Coat) | ||||||
MONITORING | Touchscreen Operator Interface, UPS Status N/O Dry Contacts, RS232C Interface (Optional RemotEye® 4 Intelligent Monitoring System) |
||||||
OPTIONS | Internal Batteries, Transformers, Dual-Input Feed, RemotEye® Intelligent Monitoring System, Remote Status Alarm Panel, Air Filters |
||||||
STANDARDS | UL 1778, CUL, ISO9001, ISO14001:2004, ANSI C62.41 (IEEE 587), NEMA/PET-1993, CE, IBC, & CBC (OSHPD) |
||||||
WARRANTY | 3-Year On-Site Warranty; 5-Year Warranty Available; See Toshiba Warranty Policy for Full Details |
||||||
SERVICE | 24-Hour, 365-Day Technical Support: 1-877-867-8773 | ||||||
* Isolation and Auto Transformer Options for Input Voltage Conversion ** Auto Transformer Options for Output Voltage Conversion *** Unit Weight Not Including Internal Battery and Transformers Specifications subject to change without notice. |
We respect your privacy and will never share your email address with anyone without your explicit permission.
N1 Critical Technologies is putting a new charge in the backup electrical power industry with the introduction of its all
Adding a maintenance bypass to your UPS will allow for proper maintenance of your UPS and also re-route utility power
N1 Critical Technologies offers a 4 hour guaranteed response time in over 98% of the United States.