Widely used in hospitals, clinics, and other medical facilities as a UPS power conditioner with battery backup, the G8000 Series offers a high crest factor that’s ideal for MRI, PET, CT and other medical devices that have a high current inrush. The G8000 has a unity power factor output that provides 20 percent more energy than what’s typical of UPS systems from other manufacturers. It’s also 100 percent generator compatible, and its low input-current harmonics eliminate the need for an oversized generator.

Features & Benefits

  • Ideal for hospitals, clinics, and other medical applications where power protection is critical
  • High crest factor is ideal for MRI, PET, CT and other medical devices that have a high current inrush
  • Unity power factor output provides 20 percent more energy than UPS systems from other manufacturers
  • 100 percent generator compatible— low input-current harmonics eliminate the need for oversized generator

Request a quote

Technical Specs

G8000 Specifications
Model #
T80S3K08KK 6XS2H
T80S3K10KK 6XS2H
T80S3K15KK 6XSNH
T80S3K22KK 6XSNH
T80S3K30KK 6XSNH
Input
Rated Output Capacity
80 KVA/80 KW
100 KVA/ 100 KW
150 KVA/150 KW
225 KVA/ 225 KW
300 KVA / 300 KW
Voltage
480 VAC (+10% to -15%)
Frequency
60 Hz (+/-5%)
Configuration
3 Phase; 3 Wire + GND
Input KW
90 KW
110 KW
165 KW
247 KW
318 KW
( 102 KW Charging)
(122 KW Charging)
(181 KW Charging)
(270 KW Charging)
(319 KW Charging)
Power Factor
> 0.99 PF Lagging
Walk-In Function
EEPROM Upgrade
Maximum Input Current
108 A Normal
135 A Normal
200 A Normal
303 A Normal
396 A Normal
(125 A Charging)
(150 A Charging)
(222 A Charging)
(338 A Charging)
(401 A Charging)
Reflected THD
< 5% Maximum @ 100% Load
6% Maximum @ 25% Load
Bypass
Configuration
Three-Phase; Four-Wire + Ground
Voltage
480/277V (±10%)
Frequency
60 Hz (±5%)
Bypass Overload Capacity
1000% for One Cycle, 500% for Two Cycles
Battery Backup
Number of Cells
180
Type
Lead Acid (Contact Factory for Alternative Options)
DC Nominal
360 V
DC Minimum
288 V
Float Charge
405 V
Ripple Current (without batteries)
AC Ripple on DC Bus: < 0.2% of DC Voltage
Back-up Time
Application Specific
Max DC Charging Current
30 A
30 A
30 A
30 A
30 A
Max Discharge
305
375
566
840
1120
Battery Capacity Required for Full Load Output
88 KWB
108 KWB
163 KWB
245 KWB
323 KWB
Output
Voltage
480Y/277V
Configuration
Three-Phase; Four-Wire + Ground
Voltage Regulation
±1% for 0 to 100%Balanced and Unbalanced Loads
Voltage Adjustment Range
±5% (In Increments of 1V)
Voltage Unbalance
±3% for 100% Linear Loads ±5% for 100% Non-Linear Loads
Crest Factor
2
Transient Voltage Response
±2% Maximum with a 100% Step Loads (Without Utilizing Batteries)
±1.5% Maximum with Loss/Return AC Input
±2% Maximum When Load Transfers To/From Bypass
Transient recovery time
< 50 ms
Frequency
60 Hz
Frequency Synchronous Range
±0.5 Hz, ±1 Hz, + 1.5Hz (Selectable)
Frequency Slew Rate
1 Hz/Sec
Frequency Regulation
±0.01% in free running mode
Current
96 A
120 A
180 A
271 A
361 A
Power Factor
1.0 PF Lagging: 32 – 86 °F (0 – 30 °C) 0.8 PF Lagging: 86 – 104 °F (30 – 40 °C)
Overload Capacity
125% for 10 Minutes, 150% for 60 Seconds
Voltage THD
< 3% Max with 100% Linear Load/5% Max with 100% Non-Linear Load
Reliability
MTBF
200,000 Hours
Efficiency
@ 25% Load
83.9%
86.4%
89.6%
87.9%
88.8%
@ 50% Load
85.3%
90.1%
91.7%
91.0%
91.7%
@ 75% Load
90.0%
91.2%
92.3%
92.3%
92.7%
@ 100% Load
90.6%
91.0%
93.0%
91.9%
92.0%
Environment
Cooling
Forced Air
Paint Color
Sherwin Williams HHT2-7055, 079 Beige Texture
Weight
1390lb. (630 kg)
1740 lb. (789 kg)
2467 lb. (1119kg)
2980 lb. (1352 kg)
4575 lb. (2075 kg)
Weight (Shipping)
1440 lb. (653 kg)
1790 lb. (812 kg)
2556 lb. (1159 kg)
3069 lb. (1392 kg)
4725 lb. (2143 kg)
Floor Loading
171 Lbs/ft2 (1037 kg/m2)
214 Lbs/ft2 (1299 kg/m2)
203 Lbs/ft2 (991 kg/m2)
245 Lbs/ft2 (1196 kg/m2)
255 Lbs/ft2 (1245 kg/m2)
Dimension – Width
36.8 in. (935 mm)
55.1 in. (1400 mm)
76.8 in. (1951 mm)
Depth
32.5 in. (826 mm)
31.8 in. (808 mm)
35.7 in. (907 mm)
Height
79.2 in. (2012 mm)
79.4 in. (2017 mm)
Power Cable Access
Bottom Access
Top or Bottom Access
Top Access
Clearance Required
Top: 15.75″ (400 mm)
Front: 43 7/16″ (1100 mm)
Back/Left/Right Sides: Zero
Enclosure
NEMA 1
Heat Loss to be Removed @ Full Load
28,387 BTUs/Hour
34,222 BTUs/Hour
44,506 BTUs/Hour
68,240 BTUs/Hour
85,300 BTUs/Hour
Audible Noise
65 DBA @ 1m Typical
68 DBA @ 1 m Typical
72 DBA @ 1 m Typical
Operating Temperature
32? to 86?F (0? to 30?C) for 1.0 PF 32? to 104?F (0? to 40?C) for 0.8 PF
Operating Humidity
30% to 90% Non-Condensing
Operating Altitude
3200 Feet (1000 m)
Listings/Standards
UL 1778; UL 17025, cUL 22.2, No. 107.1; ANSI C62.41 (IEEE 587 Cat B) NFPA 70; OSHA; ISO 9001; IEC298 IP20
Monitoring
Warranty
Three Years Parts and Labor
Dry Contacts Included
Yes for Input and Output Signals
RS232 Port
Included
Intelligent Monitoring (Optional)
SNMP; Modbus RTU; Modbus TCP; BACNET, METASYS
Display
LCD Touch-Panel for Local Monitoring, Operation, and Control
EPO
Emergency Power Off
Included
Configuration
Input Conv.
6-Diode Bridge Rectifier
Battery Cct
IGBT Chopper
Out. Inv.
IGBT Converter with PWM

 

Industries & Applications

  • Hospitals, clinics, and other medical facilities
  • “Lights-out” or “dark factory” manufacturing
  • Large data centers or IT systems
  • Critical network switching & processing equipment
  • Large-scale PLC controls

Request a quote

 

Request a Quote

Request a Quote from N1 Critical Technologies
  • Thank you for your interest on N1 Critical Technologies Inc. To contact us via email, please complete the form below and our representative will contact you. Our mailing address is 2949 Venture Drive, Suite 108 Janesville, WI 53546. Our telephone number is (855)-665-3829.

We respect your privacy and will never share your email address with anyone without your explicit permission.

 

0 replies

Leave a Reply

Want to join the discussion?
Feel free to contribute!

Leave a Reply

Your email address will not be published. Required fields are marked *